Installation 

1.  Check rough-in drawings against supplied product.
2.  Mount hanger bracket to wall. Hanger bracket MUST be securely anchored with fasteners sufficient to support 3 times 

the weight of the water cooler.

3.  Remove the bottom cover from the water cooler and set aside in a safe place. Place the screws in a safe place for re-use 

in later stages of installation.

4.  Hang the water cooler on the hanger bracket, ensuring the bracket tabs engage AND seat in the slots in the back of the 

water cooler. Verify the Water Cooler is level, straight and plumb.

5.  Anchor water cooler to wall at other mounting points in Base. If necessary, shim lower rear mounting points to level unit.
6.  Thoroughly flush the supply line and then connect water supply to water cooler.
7.  Make up trap waste connection.
8.  Flush the supply line to remove all foreign debris.
9.  Connect water supply to water cooler with 1/2” BSP
10.  Turn on building water supply and check all connections for leaks.
11.  Air within the water supply will cause an irregular bubbler outlet stream until purged out by incoming water. Covering the 

bubbler with a clean cup [or similar object] is recommended when first activating water cooler. Depress push button until 
steady water stream is achieved.

12.  Adjust bubbler to the site requirements;

13.  Plug water cooler into electrical outlet and make sure unit begins to function.
14.  Assemble bottom cover to water cooler with screws furnished.

Cleaning & Maintenance 

1.  Motors have lifetime lubrication and do not require scheduled maintenance.
2.  Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it will cycle 

on and off with no cold water coming out of bubbler. Periodically clean with vacuum cleaner, air hose or brush the 
condenser fins and cabinet ventilation louvers. In environments where dirt and dust is more prevalent, clean more 
frequently.

3.  Periodically remove access panels and clean out in-line strainer.
4.  Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void RBA warranty.
5.  Exterior panels can be cleaned using mild household detergents or warm, soapy water. Extra care must be used cleaning 

chrome plated items and mirror finished stainless steel. They can scratch easily and should only be cleaned using a 
clean, soft cloth and mild soap with water or a mild glass cleaner

Spare Parts

RBA Code No.

Description

RBA7003-095-001

Valve Assembly

RBA7003-099-000

Pushbuttton

12a. If water flow requires adjustment, insert a slotted narrow blade screwdriver in the centre of the button actuator.
      Turning clockwise will increase flow and turning counterclockwise will decrease flow.
12b. The water temperature can be adjusted using a slotted screwdriver in the cold water thermostat and turning
      clockwise to make colder and counterclockwise to make warmer.
12c. Bubbler Stream – Bubbler can be rotated slightly to direct the stream backwards or forwards.

Summary of Contents for RBA2731-032-UG

Page 1: ...er cooler 30L hr RBA2732 132 UG Wall mounted Compact stainless steel water cooler with glass filler 30L hr MODELS WALL MOUNTED COMPACT WATER COOLERS As improvements in the design and performance of RBA products are continuous specifications may be subject to change without notice The illustrations and descriptions herein are applicable to production as of the date of this Installation Instructions...

Page 2: ...imum clear space on fixture sides to allow for proper ventilation through cabinet louvers Due to cold waste water we recommend the trap supplied by installer be insulated to prevent excessive condensation Rough in and Dimensions Prior to roughing in consult with local state and federal codes for proper mounting height Installation to be done in accordance with AS NZS3500 1 and AS NZS3500 2 127 338...

Page 3: ...e requirements 13 Plug water cooler into electrical outlet and make sure unit begins to function 14 Assemble bottom cover to water cooler with screws furnished Cleaning Maintenance 1 Motors have lifetime lubrication and do not require scheduled maintenance 2 Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it will cycle on and off with no ...

Page 4: ...se wires within the compressor box The incoming power leads must be connected to the overload and relay If all components check positive for continuity then test the wiring harness plug for continuity Compressor Runs Water Is Warm The most common cause for a water cooler to run without producing cold water is a loss of refrigerant The water cooler must be taken to a certified refrigerant technicia...

Page 5: ...g condition in which the water will become frozen inside the evaporator coil This indicates a refrigeration problem or thermostat failure in which case the water cooler needs to be checked by a qualified technician Check flow adjustment If necessary adjust bubbler to site requirements see Installation Step 12 Page 3 The water cooler may also develop a freezing condition in which the water will bec...

Page 6: ...ee from the Fitting Water test the connection assembly prior to leaving the site to ensure there are no leaks 4 Prior to disconnecting the Tube from the Fitting ensure that the Water Line is depressurised Push Collet Square towards the Push In Fitting Body and hold While holding the Collet in pull on the PE Tubing to remove from the Push In Fitting Note This product should be installed by suitably...

Reviews: