V1.0 Shanghai Empower Technologies Co., Ltd. © Copy Right
www.empower.cn
BM111 SERIES 3KW Auto-Focusing Laser Cutting Heads User Manual
16 | 28
place
N/A
/
N/A
/
Focusing
enables
High-level control focus on, low-level control focus off
Lower limit
The lower limit of the input signal, active low
Upper limit
The upper limit of the input signal, active low
Note:
“N / A" is an interface without definition, please leave it blank.
The above table shows the ETC-F100 controller only for factory default settings.
To adapt the external circuit, there is a jumper cap inside the ETC_F100 to select the active-low
or active-high input signal. The output signal is selected active low or active high. To change the
signal level, contact us to change it.