1.2
STD 22 Gyro Compass
In this application the gyro compass is operated on a bus system (CAN bus). With this
application there are more extended options for connecting external equipment, and
considerably more heading receivers can be operated.
This application needs to be equipped with a minimum of a type 130-626 Operator Unit
and a type 138-118 NG002/003 Distribution Unit.
A magnetic sonde can be connected directly to the Distribution Unit.
259.8
Operator Unit
Type 130-626
12 x heading
(course bus
or NMEA)
1 x rate of turn
1 x printer (RS232)
Gyro compass
CAN--bus
Distribution unit
Type 138-118
NG002/003
Pulse Log
Pulse Log Direction
GPS Speed
GPS Position
Magnetic sensor
(option)
AC/DC converter
Type 121--062
18--36 V DC
or
24 V DC.
115--230V AC
108--010
DV--bus*
* At a Distribution Unit with a
DV--bus application no speed
and/or position inputs should
be made.
Other heading sensors
Speed and position for
Individual Speed Error
Correction
Figure 5 : STD 22 gyro compass