Operator Manual
Compass Standard 22
and
Standard 22 Compact
6
4201.DOC010102
Edition: February 2015
1.1.2
STD 22 Compact Gyro Compass optional features
1.1.2.1
Quick Settling operator unit
The “Quick Settling” function reduces the time the compass requires to settle to
approximately one hour.
The most recent heading is stored when the gyro compass is switched off. When it is
switched on the compass uses that value to make a default setting so that the settling
time is reduced.
The Quick Settling function can only be used if the ship‘s
heading has
not
been changed between switching off and
switching back on.
The Quick Settling function can
not
be used:
-- During the first setting up (installation).
-- If the ship‘s position was changed between
switching off and on again of the compass.
-- If the temperature of the gyro supporting liquid is
more than 30
C.
Running
Set
Illuminated push button
“Quick Settling ON”
Quick Settling
Figure 3
: Controls and indicators on the Quick Settling Control Unit
The “Quick Settling ON” button
activates this function.
Flashes if it is possible to activate this function.
It flashes for maximum 3 minutes.
Illuminates if the Quick Settling function is active.
Installation and assembly instructions are in the Service section of this manual.