background image

Raytheon Anschütz GmbH

Postfach 1166
D -- 24100 Kiel
Germany
Tel +49--4 31--30 19--0
Fax +49--4 31--30 19--501
Email [email protected]
www.raytheon--anschuetz.de

4201.DOC010102

Edition:

February 2015

Standard 22 Compact GYRO COMPASS

and

Standard 22 GYRO COMPASS

Type 110 --233 NG002 E01/E02

Operator manual

Summary of Contents for Standard 22 Compact

Page 1: ...el Germany Tel 49 4 31 30 19 0 Fax 49 4 31 30 19 501 Email Service raykiel com www raytheon anschuetz de 4201 DOC010102 Edition February 2015 Standard 22 Compact GYRO COMPASS and Standard 22 GYRO COMP...

Page 2: ...re liable to the payment of damages Toute communication ou reproduction de ce document toute exploitation ou communication de son contenu sont interdites sauf autorisation expresse Tout manquement cet...

Page 3: ...he STD 22 Compass 17 2 1 1 Indications on the compass during the heating stage 18 2 1 2 Indications on the compass during the settling stage 19 2 1 3 Overview of indications digital display during ope...

Page 4: ...a central Alert Panel Signal Unit Alert Panels or Signal Units must have an acoustical and optical alert indication Make sure that alerts are presented at the conning position Maintenance and repair w...

Page 5: ...stage The heading information during this settling stage has a reduced accuracy see section 2 1 2 Therefore a continuously supply with 24VDC should be gua rantied There is a reduced accuracy of the co...

Page 6: ...Operator manual Compass Standard 22 and Standard 22 Compact 4201 DOC10102 IV Edition February 2015 Intentionally left blank...

Page 7: ...elation to true north This compass provides heading information and status signals to those responsible for heading setting In principle we can distinguish between two different applications for the c...

Page 8: ...sch tz heading sensors can be connected to the Distribution Unit Outputs 2 x Heading course bus or NMEA designated CHn 1 and CHn 2 1 x Heading course bus Status signals SEC speed error correction Syst...

Page 9: ...on GPS position GPS speed Pulse Log Direction Pulse Log Status information SEC System Available Quick Settling Option 1x course bus option Additional Output Box 146 103 Step 6 steps degree NMEA option...

Page 10: ...6 The Compact STD 22 gyro compass consists of the 110 233 NG002 gyro compass the 111 006 gyrosphere Optional features QS Operator Unit 130 606 AC DC converter 121 062 Additional Output Box 146 103 The...

Page 11: ...2 DOC010102 Edition February 2015 1 1 1 STD 22 Compact Gyro Compass Scope of Supply Gyro compass with outer sphere distilled water and supporting liquid Gyrosphere packed separately Tool and spare par...

Page 12: ...ship s heading has not been changed between switching off and switching back on The Quick Settling function can not be used During the first setting up installation If the ship s position was changed...

Page 13: ...with 115 to 230 V AC on the input side and delivers 24 V DC as output voltage with a maximum output power of 240 W see separate manual no 4175 Figure 4 AC DC Converter 121 062 1 1 2 3 Additional Outp...

Page 14: ...e can be connected directly to the Distribution Unit 259 8 Operator Unit Type 130 626 12 x heading course bus or NMEA 1 x rate of turn 1 x printer RS232 Gyro compass CAN bus Distribution unit Type 138...

Page 15: ...s on the STD 22 are as follows Heading corrected SEC as NMEA or course bus Data bus CAN Bus Status signals alerts error messages RS 232 for heading and rudder position printer connection Rate of turn...

Page 16: ...als for the Operator Unit and for the Distribution Unit The Quick Settling function is activated via the Operator Unit The automatic Speed Error Correction function is available only when a GPS NMEA s...

Page 17: ...1 2 1 STD 22 Gyro Compass Scope of Supply Gyro compass with outer sphere distilled water and supporting liquid Gyrosphere packed separately Tool and spare parts pack Operator and Service manual Operat...

Page 18: ...015 1 2 2 Optional features for the STD 22 Gyro Compass 1 2 2 1 AC DC converter 121 062 The AC DC converter is supplied with 115 to 230 V AC on the input side and delivers 24 V DC as output voltage wi...

Page 19: ...3 Technical data The technical data stated here apply equally to the STD 22 Compact Gyro Compass and the STD 22 Gyro Compass 1 3 1 Mechanical data Gyro compass see dimensional drawing 110 D 233 HP005...

Page 20: ...off for a duration of min 1 hour before Speed Error Correction Automatic correction of a heading related to speed and degree of latitude see also section 2 2 Pulse log input 200 Pulses Nm Pulse log Di...

Page 21: ...Compact Gyro Compass and the STD 22 Gyro Compass Viewed from above see Figure 8 Digital indication of the following Compass heading Operating status Operating conditions requiring attention Error mes...

Page 22: ...h buttons B38 and B39 are used to adjust the settings as follows Heading and correction data Settings for functional checks System settings such as data formats or transmission speeds Only authorised...

Page 23: ...settling phase indicated by an additional dot on the digital display ends 4 hours after switching on Accuracy is now 2 No NMEA Heading and NMEA RoT is displayed output during the settling stage After...

Page 24: ...ruary 2015 2 1 1 Indications on the compass during the heating stage h heating current temperature approx 30 minutes until a temperature of 45 C has been reached The temperature for the internal follo...

Page 25: ...MEA RoT is displayed output during the settling stage Continuous light Heading indication still inaccurate For 4 hours after switching on with Quick Settling this is 1 hour Heading indication can be u...

Page 26: ...splayed during the heating stage Example h 28 8 28 8 C heating stage Settling stage lit up Example The gyro compass is settling in The heading is indicated with an illuminated dot after the last figur...

Page 27: ...depending on the alignment error a correction depending on a speed error 2 2 1 Alignment error The alignment error A error occurs if the compass was not correctly aligned when it was installed i e whe...

Page 28: ...tted screws 2 Move switch B37 DIP switch contact 1 to the OPEN position 3 The digital indicator is now indicating ALEr Alignment Error 4 Press button B38 or B39 until the heading you require displays...

Page 29: ...N OFF ON OPEN B38 B39 OPEN OR 1x 1x 176 9 176 8 176 7 176 6 B38 177 4 177 3 177 2 177 1 If the hold the button down the speed at which it changes will increase DIP switch B 37 OPEN OFF ON DIP switch B...

Page 30: ...ed heading For automatic speed error correction the ship s speed and the latitude are read into the gyro compass The speed error correction function on the STD22 Compact Gyro Compass Only the automati...

Page 31: ...e 55 55 Speed 16 Kts 16 Kts Correction value from table 1 7 1 3 True heading 345 1 7 343 3 223 7 1 3 225 Example of a bearing Compass heading 255 Latitude 55 Speed 16 Kts Direction of bearing 135 Corr...

Page 32: ...3 1 2 8 2 3 1 6 0 8 0 40 0 15 30 45 60 75 90 360 345 330 315 300 285 270 180 165 150 135 120 105 90 180 195 210 225 240 255 270 0 3 0 3 0 3 0 2 0 2 0 1 0 0 7 0 7 0 6 0 4 0 3 0 2 0 1 0 1 0 0 8 0 7 0 6...

Page 33: ...3 3 2 3 1 2 0 5 5 4 8 4 3 3 5 2 5 1 3 0 5 3 5 1 4 6 3 7 2 6 1 4 0 40 0 15 30 45 60 75 90 360 345 330 315 300 285 270 180 165 150 135 120 105 90 180 195 210 225 240 255 270 4 0 3 8 3 5 2 8 2 0 1 0 0 4...

Page 34: ...1 5 0 65 0 15 30 45 60 75 90 360 345 330 315 300 285 270 180 165 150 135 120 105 90 180 195 210 225 240 255 270 0 6 0 6 0 5 0 4 0 3 0 2 0 1 2 1 2 1 0 0 9 0 6 0 3 0 1 8 1 7 1 6 1 3 0 9 0 5 0 2 4 2 3 2...

Page 35: ...7 5 6 1 4 3 2 2 0 9 2 8 9 7 9 6 5 4 6 2 4 0 65 0 15 30 45 60 75 90 360 345 330 315 300 285 270 180 165 150 135 120 105 90 180 195 210 225 240 255 270 7 2 7 0 6 3 5 1 3 6 1 9 0 7 8 7 6 6 8 5 5 3 9 2 0...

Page 36: ...section 3 1 The flashing decimal point remains until the malfunction has been corrected Decimal point flashes on the digital display unit Please pay special attention when the compass housing is opene...

Page 37: ...ese are displayed on the compass s digital display after the B38 or B39 buttons have been pressed once 1 to 3 are displayed when button B39 is pressed and 4 6 are displayed when button B38 is pressed...

Page 38: ...2 4201 DOC010102 Edition February 2015 B38 B39 Condition 4 Examples of conditions flashing OPEN OPEN Condition 1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 C4 C5 Conditions 1 to 3 C1 C2 C3 Conditions 4 and 5 Fig...

Page 39: ...ondition is displayed To prevent overheating due to fan failure it is recommended that you do the following Check whether the fan screen is covered and check to see that air can enter the enclosure un...

Page 40: ...he compass or introduce warm air These measures should be continued until condition 2 stops It is essential that the heater be repaired at the earliest opportunity 3 1 3 Operating condition 3 Supporti...

Page 41: ...s to be performed by switching off the gyro compass The second section 3 1 4 2 can be performed without switching off the gyro compass but it must be performed very carefully and ideally under calm se...

Page 42: ...d the distilled water screw Figure 15 2 Fill in distilled water only distilled water from Raytheon Ansch tz part number 148 398 one 230cm3 bottle into the inlet for supporting liquid until the measuri...

Page 43: ...rd 22 and Standard 22 Compact 37 4102 DOC010102 Edition February 2015 distilled water vent 1 2 3 Figure 15 Immediate measure to fill up with distilled water Level OK at operational temperature appr 50...

Page 44: ...Operator Manual Compass Standard 22 and Standard 22 Compact 38 4201 DOC010102 Edition February 2015 Dip Stick top Figure 17 Dip Stick levels...

Page 45: ...must establish the cause possibly a leak and correct the fault If the level of supporting liquid is too low the compass can be destroyed Immediate measure Caution It is strongly recommended to perfor...

Page 46: ...ch 7 Figure 18 Arrangement of DIP switch Set DIP switch 7 into the upper position the follow up function is stopped Place both hands under 2 of the 4 snap closures and release them by pressing with th...

Page 47: ...ew sealing rings Place the outer sphere in the compass enclosure Pay attention to the two locking pins on the closure Hold the outer sphere with both hands and guide it under the snap closures on the...

Page 48: ...oltage cut off supporting liquid temperature does not fall to below 45 C and the voltage supply has been restored the settling stage in indicated again see also section 2 1 1 Compass indications durin...

Page 49: ...ot displayed and not output to the connected heading receivers An alert signal is indicated on the digital display by means of a flashing Erro for Error flashing OFF flashing OFF occurs only when the...

Page 50: ...Button B39 Button B38 B37 DIP switch Display Figure 21 Operating elements on the compass after removing the cover The following failed PC boards are possible PCbP power PCB faulty PCbS sensor PCB fau...

Page 51: ...L 11 PCbG Operating voltage 24V faulty E L 12 PCbG Operating voltage 15V faulty E L 13 PCbG Heating operating voltage B21 1 B21 4 faulty E L 14 PCbG Operating voltage 72V faulty E L 15 PCbG Operating...

Page 52: ...ff by switching off the power supply Caution Maintenance and repair work should be carried out only by trained and qualified staff who are well versed in national safety regulations After the gyro com...

Page 53: ...enance Supporting liquid distilled water and Pump Rotor have to be replaced every 18 24 months It is additionally recommended to clean the internal of the outer sphere and the gyro compass Instruction...

Page 54: ...Operator Manual Compass Standard 22 and Standard 22 Compact 48 4201 DOC010102 Edition February 2015 Intentionally left blank...

Reviews: