Synapsis Conning NX
Operation
___________________________________________________________________________________________________________________
41
Pos. No.
Designation
8
Manual Input
See chapter 2.5.3.1
Table 2-14
Buttons and Field Function within Sensor Page
Button / Field
Function
In automatic sensor selection (
Auto
) the CCRS uses the
best result of the integrity check as the source for the
system level data. If there are multiple best sensors the
sensor with the higher priority (according to the configured
degradation path) is used.
In manual sensor selection mode (
Manual
) the user selects
the source sensor for the system level data. As long as the
sensor delivers data, this data is used. If the sensor does
not deliver data, the CCRS switches to the next sensor in
the configured degradation path. If the best sensor
recovers, the CCRS switches back to the selected sensor. If
the user did not choose the best sensor according to the
sensor rating of the CCRS, a
BETTER SENSOR
AVAILABLE
caution is generated.
The user can exclude sensors from automatic sensor
selection. If a sensor is excluded, the sensor is not selected
even if this sensor has the best quality rating.
With placing the cursor over a sensor field a TOOLTIP pop-
up window appears after some seconds showing detailed
integrity monitoring information for the sensor.
Summary of Contents for Synapsis Conning NX