4
Basic Steps
(Quick Installation Guide P1-21/ Detailed Guide P22)
STEP 1:
Safety
Information (Pg. 2)
STEP 2:
Wiring (Pg. 6)
For PoE, use standard CAT 5 or better for both power and data. For all 8 sized
products, check the PoE detection resistance of the illuminator is compatible with
your PoE equipment (24.9K
Ω
is factory default).
For low voltage (non-PoE) apply 24V DC to red and black cores of auxiliary cable and
use standard CAT 5 or better for data connection. Connect external inputs and
external output wires as required.
IMPORTANT:
Ensure PoE equipment or 24V PSU are suitably rated
For 8 sized products check PoE detection resistance is set correctly
Ensure Cat 5 cable and auxiliary cable are correctly terminated and waterproofed after
installation
If using low voltage, a CAT 5 cable must still be connected to the network for
communication
If not using auxiliary cable, it must still be suitably terminated and waterproofed
STEP 3:
Physical Installation (Pg. 8-9)
Adjust interchangeable lens if required.
Fix to wall, pole or camera unit using U bracket provided or other Raytec bracketry.
IMPORTANT:
Ensure illuminator is rated to provide required viewing distances and select correct angle
Ensure illuminator is orientated in the correct direction