Set option flags
REc,p
Where:
c
output: 1 for light strobe output, 2 for trigger output
signal.
p
P Flag: 0 is set (positive triggers), 4 is cleared (negative
triggers).
Set the internal trigger
This command enables or disables the internal trigger. When enabled,
all outputs are triggered simultaneously using an internal trigger signal.
This setting can be saved to non-volatile memory using the
AW
command.
TT0
Disable the internal trigger.
TT1
Enable the internal trigger (using the previously set
period).
TT1,p
Enable the internal trigger and set the period.
Where:
p
= the period of the triggers in milliseconds.
For example:
TT1,200
—
Set the internal trigger to 200ms (5Hz). TT1,1s -
Set the internal trigger to 1 second (1Hz).
Simulate an input trigger
TR1
This command simulates a trigger pulse. If the channel is in pulse mode,
it emits a single pulse.
30
Summary of Contents for PULSESTAR VTS Series
Page 1: ...PULSESTAR VTS Installation Guide Issue 004...
Page 2: ...For your notes...