14.  WIRING DIAGRAMS

2

1

ELEMENT 2

1

3

ELEMENT 1

CPU

TRANSFORMER

VH1
VH2

HI-LIMIT 3

ELEMENT 3

F1 �250V/1A

Y1

1

3

1
2

1
2

WATER  OUTLET SENSOR, 150K

WATER  INLET SENSOR, 150K 

1

3

CN5

VH5

VH6

CN8

REMOTE CONTROL WIRE

1

2

3

FLOW SENSOR

2

1

2

AC POWER SUPPLY

VH3
VH4

1

2

1

OUTLET THERMISTOR OF THE CHAMBER 10K SENSOR

INLET THERMISTOR OF THE CHAMBER 10K SENSOR

CN3
CN4

GND

1

2

HI-LIMIT 2

HI-LIMIT 1

L1

L2

L1

L2

L1

L2

ELEMENT 2

1

3

1
2

1

2

1

2

WATER OUTLET SENSOR, 150K

WATER INLET SENSOR, 150K

1

3

L1

L1

GND

HI-LIMIT 2

ELEMENT 1

1

3

1

3

CPU

TRANSFORMER

VH1

VH2

CN1

CN2

CN4

VH3
VH4

CN8

1

2

3

FLOW SENSOR

REMOTE CONTROL WIRE

F1 �250V/1A

Y1

AC POWER SUPPLY

1
3

HI-LIMIT 1

Figure 6.  Wiring Diagram for Models ELS 0005 and 0011

Figure 7.  Wiring Diagram for Models ELS 0018 and 0027

Summary of Contents for ELS 0005

Page 1: ...er appliance To do so may result in an explosion or fire NOTE The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and mainten...

Page 2: ...immediate hazards which will cause severe personal injury death or substantial property damage if ignored WARNING Indicates the presence of hazards or unsafe practices which could cause severe person...

Page 3: ...EW Congratulations on the purchase of the most advanced spa pool electrical heater in the market To get the best performance and savings from your new heater it is important to install the heater in a...

Page 4: ...odels are rated operation ONLY on 240V single phase 60Hz power Heaters are flow activated No Hartford loop is required After tightening both fittings at the water heater start the pump to allow water...

Page 5: ...no circumstances should you attempt to install repair or disassemble this heater without first shutting off all power to the heater directly at the fuse or breaker box WARNING Serious bod ily injury o...

Page 6: ...ill function only when there is sufficient flow through it 15 gpm 57 lpm minimum On the digital control panel press and hold the knob for five 5 seconds to check the flow rate in the unit ELS 0005 GRN...

Page 7: ...Table D Fault Codes 11 CONTROL Turn the control knob to set your desired temperature When the set tempera ture is reached the heater will go to idle and the elements will not draw power NOTE If the c...

Page 8: ...ng must be run in a separate conduit Remote wiring must not be run parallel to high voltage lines For runs of under 30 ft 9 m remote wiring should have stranded conductors with a minimum of 22 AWG 600...

Page 9: ...at least one wire lead disconnected from each element 6 10 to 7 11 Delay in energizing elements heater starts heating 1 minute after powering up and sufficient flow is recorded 1 minute 30 secs Turn...

Page 10: ...her conditions cold high winds Defective heating element Call the electric company Calculate temperature in heat rise hr Heater input kw x 410 divided by spa gallonage This does not take into account...

Page 11: ...OF THE CHAMBER 10K SENSOR INLET THERMISTOR OF THE CHAMBER 10K SENSOR CN3 CN4 GND 1 2 HI LIMIT 2 HI LIMIT 1 L1 L2 L1 L2 L1 L2 ELEMENT 2 1 3 1 2 1 2 1 2 WATER OUTLET SENSOR 150K WATER INLET SENSOR 150K...

Page 12: ...Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A ISO 9001 REGISTERED QUALITY MANAGEMENT SYSTEM www raypak com...

Reviews: