23
REMOTE CONTROL WIRING
Important Installation Notes for Remote or External Wiring Configuration
•
Remote wiring must be run in a separate conduit.
•
Remote wiring must not be run parallel to high voltage lines.
•
For runs of under 30 feet (9.1m), remote wiring should have stranded conductors with a minimum of 22
AWG, 600V, cable twisting 1.5 to 2.5 in. (3.8 to 6.4cm) lay and jacketed.
•
For runs over 30 feet (9.1m), the conductors should be a minimum of 20 AWG, 600V, cable twisting 1.5 to
2.5 inch (3.8 to 6.4cm) lay that is shielded and jacketed.
•
Maximum cable length is 200 feet.
•
For both two- and three-wire remote systems, the provided 7-pin wiring connector must be utilized. Please
refer to the wiring instructions.
NOTE:
The remote wires must be connected to the 7-pin connector
before
the connector is plugged into the board.
2-Wire Remote Control (On-Off)
This application assumes that only one heating function (pool or spa) is required.
1. Turn on power to the heater.
2. For a 2-Wire Remote Control from a remote without its own sensor, push the MENU/SET button to the
“POOL” or “SPA” mode and set the desired setpoint (eg. 102 °F (39°C) for Spa).
3. For a 2-Wire Remote Control from a remote with its own sensor, push the MENU/SET button “POOL” or
“SPA” mode and set the temperature to the highest setting available on the control. The actual setpoint will
be controlled by the remote control.
4. Turn the MENU/SET button to "OFF" and remove power from the heater.
5. On the "Remote Interface Harness", connect the BLUE wire to one side of the "REMOTE" switch and con-
nect the other side to either the ORANGE/BLACK wire for "SPA" operation or the BLACK/ORANGE wire for
"POOL" operation.
6. Attach wire nut on unused wire to the "Remote Interface Harness."
7. Install the "7-Pin Remote Interface Harness" to the P8 connector and turn power “On” to the heater.
To activate the remote control, see page 20.
3-Wire Remote Control Using Three-Position Switch (Pool-Off-Spa, or Low-Off-High)
This application assumes that both heating functions (pool and spa) are required.
1. Turn on power to the heater.
2. Push the menu/set button to the "POOL" or "SPA" mode and set the desired temperature for each (eg. 80°F
(27°C) for Pool and 102°F (39°C) for Spa).
3. Turn the MENU/SET button to "OFF" and remove power from the heater.
4. On the "Remote Interface Harness" connect the BLUE wire to one side of the "REMOTE" switch and con-
nect the ORANGE/BLACK wire for "SPA" operation and the BLACK/ORANGE wire for the "POOL"
operation.
5. Install the "Remote Interface Harness" to the P8 connector and turn power "ON" to the heater.
To activate the remote control, see page 20.
P8 Connector
Wire Nut - BLK/ORN
To Pool (COMM)
ORN/BLK - To Spa (COMM)
BLU - 24VAC
AFT Board
P8 Connector
ORN/BLK - To Spa (COMM)
BLU - 24VAC
BLK/ORN - To Pool (COMM)
AFT Board
2-Wire Remote Control
3-Wire Remote Control
Summary of Contents for 106
Page 18: ...18 ...
Page 24: ...24 Wiring Diagrams Fig 19 Wiring Diagram Analog Models Fig 20 Wiring Diagram Digital Models ...