background image

5

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

AUX

ANT

^^^^

AUX

ANT

AUX ANT

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

Press and 
release the 
LEARN button 
(LED will light).

BASIC PROGRAMMING

TIMER DEFEAT

The TTC can be temporarily disabled by pressing a STOP button. TTC will become enabled after the next open command.

1

2

3

CLEAR THE TIMER-TO-CLOSE (TTC)

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

Press and hold 
the TTC button 
for 6 seconds.

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

Release the 
TTC button 
(LED will go 
out). The TTC 
will no longer 
be active.

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

Press and 
release the 
TTC button.

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

AUX

ANT

^^^^

AUX

ANT

AUX ANT

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

O

PEN

Press and hold 
the LEARN button 
(LED will light).

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

Every press and release 
of the STOP button 
will add 5 seconds to 
the Timer-to-Close. 
Example: 30 second 
TTC = 6 presses of the 
STOP button.

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

Press and release 
the TTC button to 
exit programming 
mode. The LED 
will fl ash once per 
5 seconds of timer 
setting.

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

Press and 
release the 
TTC button.

3

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

AUX

ANT

^^^^

AUX

ANT

AUX ANT

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

O

PEN

Press and 
release the 
LEARN button 
(LED will light).

TIMER-TO-CLOSE (TTC)

TO PROGRAM

Begin with door in fully closed position.

Timer-to-Close feature enables the operator to close from the open limit after a preset time, adjustable from 5 to 60 seconds. 

Requires 

LiftMaster Monitored Entrapment Protection (LMEP) device.

1

2

4

1

2

3

TO VERIFY TIMER-TO-CLOSE (TTC) SETTING

The TTC will become active after completion of the next open cycle.

 

NOTE:

 The LED does not indicate that timer is running.

D14

COM

INTRLK

STOP

LED

OPEN

CLOSE

TTC

LEARN

1

LMEP1

LMEP2

23

4

5

6

7

ST
OP

CLOSE

OPEN

R27

Press and release the TTC button a 
second time. The LED will fl ash once 
per 5 seconds of timer setting.

Summary of Contents for MT5011UCHB

Page 1: ...Radio Receiver Built on Board 315 MHz Installation Date CONTACT INFORMATION MEDIUM DUTY LOGIC USER S GUIDE MH5011URCHB MH5011ULCHB MT5011UCHB MJ5011UCHB www Raynor com...

Page 2: ...is released before reaching the close limit BASIC PROGRAMMING RECOMMENDED INSTALLATION B2 WIRING TYPE WITH MONITORED ENTRAPMENT PROTECTION DEVICE Momentary contact to open close and stop Open overrid...

Page 3: ...Logic Board Electrical Box D14 LED LEARN 1 2 3 4 5 6 7 STOP CLOSE OPEN ALTERNATE INSTALLATION C2 WIRING TYPE WITHOUT MONITORED ENTRAPMENT PROTECTION DEVICE FACTORY DEFAULT Momentary contact to open an...

Page 4: ...D OPEN CLOSE TTC LEARN 1 LMEP1 LMEP2 2 3 4 5 6 7 STOP CLOSE OPEN R27 AUX ANT AUX ANT AUX ANT D14 COM INTRLK STOP LED OPEN CLOSE TTC LEARN 1 LMEP1 LMEP2 2 3 4 5 6 7 STOP CLOSE OPEN TO ERASE ALL REMOTE...

Page 5: ...3 4 5 6 7 STOP CLOSE OPEN R27 Every press and release of the STOP button will add 5 seconds to the Timer to Close Example 30 second TTC 6 presses of the STOP button D14 COM INTRLK STOP LED OPEN CLOSE...

Page 6: ...Press CLOSE button The door should move in the close direction Release CLOSE button Door should stop if in C2 mode The door should continue closing if in B2 mode Press STOP button The door should stop...

Page 7: ...f the emergency release handle Emergency disconnect will close TO DISCONNECT DOOR FROM OPERATOR TO RECONNECT DOOR ARM TO TROLLEY 1 1 2 3 Emergency Disconnect Door Arm To prevent possible SERIOUS INJUR...

Page 8: ...hoist operation Refer to Model MJ instructions for emergency operation When the manual chain hoist sash chain is engaged electrical operation will not function 1 2 Keyhole Bracket EMERGENCY DISCONNEC...

Page 9: ...dealer DOOR REVERSES UNEXPECTEDLY Entrapment protection device activated Verify photoelectric sensors are aligned If photoelectric sensors are aligned and operator still does not operate properly con...

Page 10: ...10 OPERATOR NOTES...

Page 11: ...Button SECURITY Remote Control Includes visor clip Wireless Single Push Button Control SECURITY Rugged composite housing Wireless controls cannot be used in place of hard wired controls 1 2 4 5 7 8 0...

Page 12: ...d at the Open limit Input functions as Open input at all other times Also used with external radio controls 71 MLMOTION Door In Motion Provides dry contact and a terminal block with contacts switched...

Reviews: