INSTALLATION STEP 2

Install the Header Bracket

You can attach the header bracket either to the wall above 
the garage door, or to the ceiling. Follow the instructions 
which will work best for your particular requirements. 

DO NOT install the header bracket over drywall. 
If installing into masonry, use concrete anchors 
(not provided).

WALL HEADER BRACKET INSTALLATION

•   Center the bracket on the vertical centerline with the 

bottom edge of the bracket on the horizontal line as 
shown (with the arrow pointing toward the ceiling). 

•    Mark the vertical set of bracket holes (do not use the 

holes designated for ceiling mount). Drill 3/16" pilot 
holes and fasten the bracket securely to a structural 
support with the hardware provided.

HARDWARE SHOWN ACTUAL SIZE

CEILING HEADER BRACKET INSTALLATION

•   Extend the vertical centerline onto the ceiling as 

shown.

•   Center the bracket on the vertical mark, no more than 

6" (15 cm) from the wall. Make sure the arrow is 
pointing toward the wall. The bracket can be mounted 
fl ush against the ceiling when clearance is minimal.

•    Mark the side holes. Drill 3/16" pilot holes and fasten 

bracket securely to a structural support with the 
hardware provided.

Header Bracket

2x4 Structural 
Support

Vertical Centerline 
of Garage Door

Optional Wall 
Mounting Holes

Lag Screws 
5/16"-9x1-5/8"

Vertical Centerline 
of Garage Door

Door Spring

Highest Point 
of Garage 
Door Travel

Horizontal 
Line

- Header Wall -

Wall Mounting Holes

Ceiling Mounting Holes

Door 
Spring

6" (15 cm) 
Maximum

Lag Screws 
5/16"-9x1-5/8"

Header 
Bracket

Vertical 
Centerline of 
Garage Door

Vertical 
Centerline of 
Garage Door

Garage Door

The nail hole is for 
positioning only. 
You must use lag 
screws to mount the 
header bracket.

The nail hole is for 
positioning only. 
You must use lag 
screws to mount the 
header bracket.

- Header Wall -

- Finished Ceiling -

- Garage Door -

Lag Screw 
5/16"-9x1-5/8"

Summary of Contents for 3245RGD 1/3 HP

Page 1: ...LL NOT CLOSE unless the Protector System is connected and properly aligned Periodic checks of the opener are required to ensure safe operation The model number label is located on the front panel of y...

Page 2: ...r 28 Having a problem 29 Diagnostic chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change a Keyless Entry PI...

Page 3: ...lement Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or...

Page 4: ...r is closed Support bracket fastening hardware is required See page 11 Motor Unit FINISHED CEILING Wall Mounted Door Control Extension Spring OR Torsion Spring Header Wall Access Door Safety Reversing...

Page 5: ...Washer 5 16 4 Screw 6ABx1 1 4 2 Screw 6 32x1 2 Self Threading Screw 1 4 14x5 8 2 Insulated Staples 30 Ring Fastener 3 Drywall Anchors 2 Carriage Bolt 1 4 20x1 2 2 Wing Nut 1 4 20 2 Rope Handle SAFETY...

Page 6: ...nut on the trolley to obtain more chain slack Insert the second washered bolt CAUTION Use only the bolt previously removed from motor unit Tighten both bolts securely through the rail into the motor...

Page 7: ...balanced and lubricated garage door An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH 3 ALL repairs to cables spring assemblies and other hardware MU...

Page 8: ...r the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possibl...

Page 9: ...e ceiling as shown Center the bracket on the vertical mark no more than 6 15 cm from the wall Make sure the arrow is pointing toward the wall The bracket can be mounted ush against the ceiling when cl...

Page 10: ...s not tall enough Open the door all the way and place a 2x4 laid at on the top section beneath the rail If the top section or panel hits the trolley when you raise the door pull down on the trolley re...

Page 11: ...line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to op...

Page 12: ...allowing 1 8 3 mm to protrude above wall surface Position bottom of door control on screw head and slide down to secure Adjust screw for snug t Install top screw with care to avoid cracking plastic ho...

Page 13: ...he hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the oor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Sec...

Page 14: ...Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Rei...

Page 15: ...eiving eye lens The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be s...

Page 16: ...oor Attach brackets to wall with lag screws not provided If using extension brackets or wood blocks adjust right and left assemblies to the same distance out from the mounting surface Make sure all d...

Page 17: ...ollow the instructions below Cut the end of the safety reversing sensor wire making sure there is enough wire to reach the pre installed wires from the wall Figure 7 Separate the safety reversing sens...

Page 18: ...orrect wiring between sensors and opener A broken wire 2 If the sending eye indicator light glows steadily but the receiving eye indicator light doesn t Check alignment Check for an open wire to the r...

Page 19: ...epending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracke...

Page 20: ...he door if required for your installation Refer to the dotted line optional placement drawing HARDWARE SHOWN ACTUAL SIZE Self Threading Screw 1 4 14x5 8 WOOD DOOR METAL DOOR Finished Ceiling HORIZONTA...

Page 21: ...alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sec...

Page 22: ...tton The trolley will travel to the fully closed position Figure 5 Figure 6 Manually close the door and lift the door arm to the trolley The arm should touch the trolley just ahead of the door arm con...

Page 23: ...ce as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the DOWN limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won...

Page 24: ...by turning the control clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the...

Page 25: ...bstruction and run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY...

Page 26: ...trol is activated Bulb size is 100 watts maximum SAFETY SIGNAL light feature Lights will also turn on when someone walks through the open garage door With a Multi Function Door Control this feature ma...

Page 27: ...on To turn off press and hold the Lock button again for 2 seconds The push bar light will stop ashing The Lock feature will also turn off whenever the learn button on the motor unit panel is activate...

Page 28: ...tteries DO NOT recharge disassemble heat above 100 C 212 F or incinerate Care of Your Opener LIMIT AND FORCE ADJUSTMENTS Weather conditions may cause some minor changes in door operation requiring som...

Page 29: ...to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adjust the UP...

Page 30: ...or unit Momentarily short across red and white terminals with jumper wire If motor unit activates replace door control wires Symptom Sending indicator light glows steadily receiving indicator light is...

Page 31: ...be heard 1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote that...

Page 32: ...ights will blink once when the PIN has been learned Test by pressing the new PIN then press Enter The door should move To set a temporary PIN You may authorize access by visitors or service people wit...

Page 33: ...hium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope handle assembly 6 41B4494 1 2 Conductor bell wire white white red 7 41A4353 Header bracket with clevis pin fastener 8 4...

Page 34: ...ring assembly RPM sensor KEY PART NO NO DESCRIPTION 11 41A5525 25 Cover 12 41A2818 Limit switch drive retainer 13 41D3452 Limit switch assembly 14 41A2822 1 Interrupter cup assembly 15 41C4398A RPM se...

Page 35: ...Includes visor clip Outside Keylock Opens the garage door automatically from outside when remote control is not handy 8 foot 2 4 m Complete Rail To allow an 8 foot 2 4 m door to open fully 10 foot 3 m...

Page 36: ...o you THIS LIMITED WARRANTY DOES NOT COVER NON DEFECT DAMAGE DAMAGE CAUSED BY IMPROPER INSTALLATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESS...

Reviews: