8
ST7002 SmartPilot Controller Operating Guide
3. Press
disp
or wait for 5 seconds to return to the previous display.
Adjusting performance – Non-G systems
Non-G SmartPilot systems have three different response levels:
• Response Level 1: AutoSeastate on (Automatic deadband)
The SmartPilot will gradually ignore repetitive boat movements and only
react to true variations in course. This provides the best compromise between
power consumption and course keeping accuracy.
• Response Level 2: AutoSeastate off (Minimum deadband)
This setting provides tighter course keeping but will lead to increased power
consumption and drive unit activity.
• Response Level 3: AutoSeastate off + yaw damping
This setting provides the tightest possible course keeping by introducing
counter rudder yaw damping You can adjust the counter rudder setting in
Dealer Calibration (see
SmartPilot Commissioning Guide
).
To make a
temporary
change to the response setting:
1. Display the
RESPONSE
screen by pressing either the
resp
button or the
-1
and
+1
buttons together.
2. Press
-1
or
+1
or the up arrow or down arrow buttons to change the response
between levels 1 to 3.
3. Press
disp
or wait for 5 seconds to return to the previous display.
Note:
You will lose these temporary changes to response level whenever the system is
powered off. You can make permanent adjustments in User Calibration (see page 24).
D5453-2
Increase
response
Decrease
response
Summary of Contents for SmartPilot ST7002
Page 1: ...ST7002 SmartPilot Controller Operating Guide Document reference 81270 1 Date December 2005...
Page 6: ...iv ST7002 SmartPilot Controller Operating Guide...
Page 10: ...viii ST7002 SmartPilot Controller Operating Guide...
Page 36: ...26 ST7002 SmartPilot Controller Operating Guide...
Page 44: ...34 ST7002 SmartPilot Controller Operating Guide...
Page 48: ...38 ST7002 SmartPilot Controller Operating Guide...
Page 51: ...41...
Page 52: ...42...