Chapter 2: Commissioning
21
Enter Dealer Calibration mode
As improper use of the Dealer Calibration settings can seriously impair SmartPilot
performance, we have made entry to the Dealer Calibration mode more difficult.
Ensure you follow the instructions in this step carefully.
1. Start with the SmartPilot in
STANDBY
mode.
2. Enter
DEALER CAL
as follows:
Note:
For more information on SmartPilot settings, refer to Chapter 3:
Set the vessel type
When you select a vessel type, the SmartPilot automatically selects appropriate
default values for various other calibration settings.
Some of these settings will be checked later in this procedure and the remaineder
should not require any adjustment. The default values for each vessel type are
listed on
page 52
.
To set the vessel type:
1. Use the
disp
key to scroll through the Dealer Calibration pages until the dis
play shows either
VESSEL
or one of the vessel types (e.g.
DISPLACE
).
2. Use the
1
or
+1
keys to select SAILBOAT:
To enter DEALER CAL:
• press and hold the
standby
key for two seconds to enter the Calibration mode
• when the screen shows
DISPLAY CAL
, press the
disp
key until you see the
DEALER CAL
screen
• press the
auto
key: the display will change to
CAL?
• press
1
and
+1
together to enter Dealer Calibration mode
At the CAL ? screen, press + together to enter DEALER CAL
2 sec
x3
-1
+1
D9325-1
81282_1.book Page 21 Monday, October 2, 2006 1:58 PM
All manuals and user guides at all-guides.com