background image

1.

Primary station.

2. Raymic handset extension cable (A80290, A80291 or A80292)

3.

Raymic handset second station (A80289)

4.

Panel mount fixings kit (R70438)

5. Raymic handset adaptor cable with RCA audio (A80297)

6. Primary station passive speaker

7.

Second station passive speaker

Note:

As the Fistmic does not include a display it cannot be

used to create a second functional station.

Alarm behavior for second station passive speakers (applies to
Ray60 / 70 only)

The A80297 adaptor cable can be used to connect an additional
passive speaker to the second handset station. A passive speaker
connected to the second station of a

Ray60

or

Ray70

Radio will

only receive voice audio. Alarms will NOT be heard from the
passive speaker when it is connected to the second station of a

Ray60

or

Ray70

Radio.

Ray90 - Ray91

Handset station connection

A Wired handset can be connected to each Handset station
connection (HS 1 / HS 2). Your radio is supplied with the equipment
to create a full handset station (i.e.: Wired handset, Adaptor cable
and Passive speaker). Additional accessories can be purchased
to create a second wired handset station.

1.

Base station

2. Passive speaker (1 x supplied and available as accessory:

A80542)

3.

Wired handset (1 x supplied and available as accessory:
A80289)

4.

Handset station adaptor cable with RCA Audio 400 mm (1.3 ft)
(1 x supplied and available as accessory: A80297)

5. Wired handset extension cable (Available optional

accessories: A80290 – 5 m, A80291 – 10 m or 15 – A80292)

6. Panel mount fixings kit (1 x supplied and available as a Spare:

R70438)

Connecting handsets and cables

Follow the steps below to connect handsets and extension cables
together.

1. If fitted, unscrew and remove the dust cap from the relevant

connector.

2. Ensure the cable connectors are correctly orientated, before

insertion.

3. Ensure connectors are fully inserted, before locking..
4. Tighten locking collars by Rotating clockwise.

Handset extension cables

Handset station cabling can be extended using approved
extension cables.

The maximum length of cable from the Handset to the Base station
should not exceed 50 m (164 ft)

Handset (wired) mounting using the
holster

Before mounting, ensure that your selected location meets the
location requirements found in this document.

1. Check the selected location for the mounting holster, a clear

flat area is required, with sufficient space around it to place
and remove the Handset.

2. Using a pencil, offer up the holster to the desired location and

mark the location of the screw holes on the mounting surface.

3. Drill the mounting holes using a suitable size drill bit.
4. Hold the holster in place and secure using the screws provided.
5. Place the Handset into the holster until it clicks into position.

Pass-through panel kit mounting

When installing handsets, the pass-through panel kit should be
used to secure the cable to any panels the cable has to pass
through.

Raymic wired handset installation instructions

3

Reviews: