Waterline offset
2
Transducer / Zero offset
3
Keel offset
If an offset is not applied, displayed depth readings represent the
distance from the transducer to the sea bed.
Calibrating Bidata
During normal operation:
1. Simultaneously press and hold the
Down
and
Action
buttons
for 2 seconds to display the user cal page.
1
0
15
20
25
30
35
40
45
50
55
60 5
2
+
D12414-1
2. Press the
Action
button to display the depth response page.
CAL
D12401-1
3. Use the
Up
and
Down
buttons to adjust the depth response to
the required level.
4. Press the
Action
button to display the speed response page.
CAL
D12410-1
5. Use the
Up
and
Down
buttons to adjust the speed response to
the required level.
6. Press the
Action
button to display the depth units page.
CAL
D12402-1
7. Use the
Up
and
Down
buttons to select the required depth units.
8. Press the
Action
button to display the speed units page.
CAL
D12411-1
9. Use the
Up
and
Down
buttons to select the required speed units.
10. Press the
Action
button to display the distance units page.
CAL
D12403-1
11. Use the
Up
and
Down
buttons to select the required distance
units.
12. Press the
Action
button to display the water temperature units
page.
CAL
D12412-1
13. Use the
Up
and
Down
buttons to select the required temperature
units.
14. Press the
Action
button to display to the cal factor page.
CAL
D12398-1
15. Use the
Up
button to increase the cal factor value, or the
Down
button to decrease the cal factor value.
16. Alternatively, simultaneously press and hold the
Up
and
Down
buttons to display the SOG page.
CAL
D12409-1
+
The SOG page is only displayed if SOG data is available and the
vessel speed is greater than 0.5 kts.
17. In conditions of zero tide and current, press the
Up
button for 3
seconds to apply the SOG value as the speed reading.
18. Press the
Action
button to display the depth offset page.
CAL
D12400-1
19. Use the
Up
and
Down
buttons to select the required depth offset
value.
20. Press the
Action
button to display the shallow alarm lock page.
C
AL
D12407-1
21. Use the
Up
and
Down
buttons to switch the shallow alarm lock
on and off.
22. To save your settings and return to normal operation from any
page, simultaneously press and hold the
Down
and
Action
buttons for 2 seconds.
Calibrating depth
During normal operation:
1. Simultaneously press and hold the
Down
and
Action
buttons
for 2 seconds to display the user cal page.
1
0
15
20
25
30
35
40
45
50
55
60 5
2
+
D12414-1
2. Press the
Action
button to display the depth response page.
CAL
D12401-1
3. Use the
Up
and
Down
buttons to adjust the depth response to
the required level.
Getting started
31
Summary of Contents for i40
Page 2: ......
Page 4: ......
Page 6: ...6 i40...
Page 16: ...16 i40...
Page 26: ...26 i40...
Page 34: ...34 i40...
Page 42: ...42 i40...
Page 43: ...Chapter 8 Using alarms Chapter contents 8 1 Alarms on page 44 Using alarms 43...
Page 56: ...56 i40...
Page 62: ...62 i40...
Page 67: ......
Page 68: ...www raymarine com...