Power up troubleshooting
Product does not turn on or keeps turning off
Possible causes
Possible solutions
Blown fuse / tripped breaker
1.
Check condition of relevant fuses and breakers and connections, replace if
necessary (Refer to
Chapter 9 Technical specification
for fuse ratings.)
2.
If fuse keeps blowing check for cable damage, broken connector pins or
incorrect wiring.
Poor / damaged / insecure power supply
cable / connections
1.
Check the unit’s connector for broken or bent pins.
2.
Check that the cable connector is fully inserted into the unit and that the locking
collar is in the locked position.
3.
Check the power supply cable and connectors for signs of damage or corrosion,
replace if necessary.
4.
With the unit turned on, try flexing the power cable near to the display connector
to see if this causes the unit to re-boot/loose power, replace if necessary.
5.
Check the vessel’s battery voltage, the condition of the battery terminals and
power supply cables, ensuring connections are secure, clean and free from
corrosion, replace if necessary.
6.
With the product under load, using a multi-meter, check for high voltage drop
across all connectors/fuses etc (this can cause the Fishfinder applications to
stop scrolling or the unit to reset/turn off), replace if necessary.
Incorrect power connection
The power supply may be wired incorrectly, ensure the installation instructions have
been followed. (Refer to
Chapter 4 Cables and connections
for cable and connection
requirements.)
Power source insufficient
With the product under load, using a multi-meter, check the power supply voltage as
close to the unit as possible to establish actual voltage when the current is flowing.
(Refer to
Chapter 9 Technical specification
for power supply requirements.)
Product will not boot up (re-boot loop)
Possible causes
Possible solutions
Power supply and connection
See possible solutions from ‘Products does not turn on or keeps turning off’ above.
Software corruption
1.
In the unlikely event that the products software has become corrupted please
try re-flashing the latest software from the Raymarine website.
2.
On display products, as a last resort, you can try to perform a ‘Power on Reset’,
however this will delete all settings/presets and user data (such as waypoints
and tracks) and revert the unit back to factory defaults.
40
ECI–100
Summary of Contents for eci-100
Page 2: ......
Page 4: ......
Page 6: ...6 ECI 100 ...
Page 12: ...12 ECI 100 ...
Page 31: ...Chapter 5 Mounting Chapter contents 5 1 Mounting the unit on page 32 Mounting 31 ...
Page 48: ...48 ECI 100 ...
Page 54: ...54 ECI 100 ...
Page 56: ...56 ECI 100 ...
Page 57: ......