background image

?

More information....

See the 'Using the Fishfinder' chapter of the Reference Manual.

D8945_1

What's under the boat?

Using the fishfinder....

Card No. 16

TRANSDUCER

SETTINGS

ZOOM

BOTTOM LOCK

A - SCOPE

PRESENTATION

How do I change the range or shift the image?

How do I zoom in on an area of the screen?

How do I change the operating frequency?

Your system automatically adjusts the display depth range, selecting the shallowest depth that keeps the 

bottom  on  the  lower  half  of  the  window.  You  can  however,  set  this  manually  if  required  and  move  the 

image within the selected page up or down. Using the range controls will affect all fishfinder windows.

IN - decrease depth.

OUT - increase depth.

Press RANGE

(IN or OUT)

Turn to alter

shift value.

Select zoom level

Select MAN

Select DUAL

frequency mode

Select required

frequency

To see more detail of the bottom structure, target images etc, zoom in and enlarge a portion of the image. 

How do I change the gain mode?

Select gain level

ZOOM...

ZOOM FACTOR

x2   x3   x4  xR

ZOOM

ON   SPLIT   OFF

Toggle as required

FISHFINDER

SETTINGS...

Both 

- 200 kHz & 50 kHz displayed 

simultaneously. Only available if 

FREQ MODE set to DUAL.

50 kHz

 -  for maximum depth 

penetration in deep water.

200 kHz

 - for maximum 

definition in shallow water.

Auto mode - 

automatically selects 50 kHz or 200 kHz.  This is the default mode. 

The system automatically adjusts the gain control to display the sharpest image.  If required, you can select 
the gain level to suit your fishing mode:

To define the gain mode still further, select manual gain mode and then adjust the level using the rotary control.

Manual (MAN) - Single or dual

High

 - when fishing

Low 

- when cruising

Med

 - when trolling

On 

- zooms fishfinder image 

Split

 - displays zoomed image and standard fishfinder image simultaneously.

Zoom

D6585-1

RANGE

IN

OUT

D6585-1

RANGE

IN

OUT

Turn

RANGE

AUTO    MAN

RANGE SHIFT

xx FT

FREQUENCY

AUTO     MAN

FREQ MODE

SINGLE    DUAL

SELECT FREQ

200   50   BOTH

FISHFINDER

SETTINGS...

GAIN ...

GAIN MODE

AUTO   MAN

AUTO GAIN

LO    MED   HIGH

OK

Summary of Contents for C120

Page 1: ......

Page 2: ...place waypoint at your boat s position Press and hold to place a Man Overboard MOB marker at your current position Press and hold again to exit MOB RANGE Press to change the display scale so that a s...

Page 3: ...hlight the next option If a key displays a single value or a slider above use the rotary control to adjust Within the text of this document they are written in capitals e g SORT LIST Buttons Soft keys...

Page 4: ...onfirm Highlight required page set Note Alternatively you can display the Select Page Set screen via the Menu key To customise EDIT PAGE SET Follow on screen instructions Or PAGE OK PAGE ACTIVE SOFT K...

Page 5: ...ackpad up down to highlight and then right to select CF CARD REMOVAL The system will now complete its checks When instructed to do so open the chart card door and remove the card Firmly click the char...

Page 6: ...sor When cursor reaches window edge chart pans to a different area Press and hold to pan larger areas Press RANGE OUT to see a larger area of the chart Press RANGE IN to see a smaller area in more det...

Page 7: ......

Page 8: ......

Page 9: ...CDI windows The details of each waypoint are stored in a waypoint list 1000 waypoints maximum Waypoints can be renamed edited grouped or erased as necessary To make full use of waypoint features ensu...

Page 10: ......

Page 11: ...ations that you make a nearby small object may appear the same size on the screen as a distant large object However with experience the approximate size of different objects can be determined by the r...

Page 12: ......

Page 13: ...et tracking and risk analysis MARPA improves your standards of collision avoidance by obtaining detailed information for up to 10 targets and provides continuous and rapid situation evaluation MARPA t...

Page 14: ...unds and target flashes Activated target Target activated i e AIS vector displayed Vector line optional shows predicted distance travelled within given time Uncertain target Calculated CPA TCPA value...

Page 15: ...Press DATA CHART VECTORS COG HDG VECTORS Use the Course Deviation Indicator CDI With your display receiving accurate heading and position information you can monitor your course and accurately steer t...

Page 16: ......

Page 17: ...e a portion of the image How do I change the gain mode Select gain level ZOOM ZOOM FACTOR x2 x3 x4 xR ZOOM ON SPLIT OFF Toggle as required FISHFINDER SETTINGS Both 200 kHz 50 kHz displayed simultaneou...

Page 18: ...ss the appropriate soft key to select the panel of your choice To view data from 3 engines change the No of engine setting in the Panel Setup Menu More information If connected to a Navtex receiver yo...

Page 19: ...nchester Street Merrimack NH 03054 4801 USA 1 800 539 5539 www raymarine com D6826_4 Raymarine Ltd Quay Point Northarbour Road Portsmouth Hampshire England PO6 3TD 44 0 23 9269 3611 www raymarine com...

Reviews: