1.
Positive (+) bar
2. Negative (-) bar
3.
Circuit breaker
4.
Waterproof fuse holder with 5 A inline fuse must be fitted (not supplied).
Important:
Observe the recommended fuse / breaker ratings provided in the product’s documentation,
however be aware that the suitable fuse / breaker rating is dependent on the number of devices
being connected.
Implementation — direct connection to battery
• SeaTalkng ®Where connection to a power distribution panel is not possible, the power cable may
be connected to the vessel's battery..
• You MUST fit a suitably rated fuse or breaker between the red wire and the battery’s positive
terminal.
• Refer to the inline fuse ratings provided in the product’s documentation.
• If you need to extend the length of the power cable, ensure you use suitably rated cable and that
sufficient power (12 V dc) is available at the SeaTalkng ® backbone’s power connection.
Summary of Contents for AR200
Page 1: ...Installation instructions AR200 ...
Page 7: ...Chapter 2 Document information Chapter contents 2 1 Product documentation on page 14 ...
Page 13: ...Chapter 4 Parts supplied Chapter contents 4 1 Parts supplied on page 20 ...
Page 15: ...Chapter 5 Product dimensions Chapter contents 5 1 Product dimensions on page 22 ...
Page 16: ...5 1 Product dimensions ...
Page 17: ...Chapter 6 Location requirements Chapter contents 6 1 Selecting a location on page 24 ...
Page 55: ...Chapter 11 Operation Chapter contents 11 1 Operation instructions on page 64 ...