0049-2702-XXX Alliance Series Modems – USER MANUAL
08/05/2010
Rev. A
Page 3 of 197
For leased line applications:
•
Use the supplied four-conductor cable to connect the modem connector labeled
“LEASED LINE” into the leased line modular wall jack (type USOC JM8). Do not
bundle the leased line and TIA/EIA interface cables together.
If your application requires an 8-pin connector, use the alternate leased line connector
shown in Figure 1-1 instead of the 6-pin “LEASED LINE” connector. To use the
alternate connector, you will need to provide your own cable. (See Appendix A for pin-
out information.)
The same cable is used whether the leased line is a 4-wire or 2-wire line. In a 4-wire
application, the green and red wires are the TRANSMIT pair, and the yellow and black
wires are the RECEIVE pair. For a 2-wire line, only the green and red wires are used.
Figure 1-1. Installation of the ALX modem