![Raydon RA-530 Series User Manual Download Page 9](http://html.mh-extra.com/html/raydon/ra-530-series/ra-530-series_user-manual_789706009.webp)
RAYDON Electronics Technology Co., Ltd.
Phone: +86 20 8478 1227 Fax: +86 20 3478 1237
Web Site:
http://www.batterytesting.com.cn
eMail: [email protected]
Page 7 of 70 Pages
R
R
R
R
R
R
R
R
A
A
A
A
A
A
A
A
Y
Y
Y
Y
Y
Y
Y
Y
D
D
D
D
D
D
D
D
O
O
O
O
O
O
O
O
N
N
N
N
N
N
N
N
1.4.6.
Capacity Test
Two steps process to fully charge and then fully discharge the battery pack with medium current rate and display
the battery’s capacity value at the last result display screen.
Step description:
Step
Type
Mode
Set Value
Current Output
Terminate Conditions
1
Charge
CV
4.2V/cell
0.5C
Current < 0.05C
2
Discharge
CC
0.5C
0.5C
Volt < 3.0V/cell
1.4.7.
Battery Performance Recovering Cycle - Re-Learning Cycle
Four steps process to re-learn the battery pack with medium current rate and update the battery’s FCC value to its
accurate level.
Step description:
Step
Type
Mode
Set Value
Current Output
Terminate Conditions
1
Discharge
CC
0.5 C
0.5C
Volt < 3.0V/cell
2
Charge
CV
4.2V/cell
0.5C
Current < 0.05C
3
Discharge
CC
0.5C
0.5C
Volt < 3.0V/cell
4
Charge
CV
4.2V/cell
0.5C
Volt > 4.1V/cell