5.4.
Instant Report Generator
The RA-530 laptop battery analyzer and re-conditioner is a standalone configuration, it was designed to work by itself with
all the testing controls and battery database build-in. RA-530 is able to show the test result on the LCD display in the
tester’s front panel but failed to record these results once the channel is reset and another test is carried out on the same
channel.
Instant Report Generator function allows user to capture the latest test result from a selected testing channel and put it
into a printed format for recording and documentation.
Once the connection is made between computer and RA-530, user can retrieve laptop battery information and/or testing
results from the selected channel under the following conditions:
Channel Selection:
The channel is selected on the RA-530 front panel channel control area. User can switch between different channels
by pressing the Channel Selection Button of the respective channel and the LED on the button will indicate the
selection. RA-530 will only return laptop battery information and/or testing results from that single selected channel.
If user wants to retrieve information from multiple channels, user must perform the data retrieval on one channel at
a time and change to another channel after the instant report is generated.
Channel States:
RA-530 only allows the software to retrieve the battery information when the selected channel is at READY or FINISH
state.
When the channel is at READY state, the laptop battery information is mainly the SMBus parameters store in the
battery register. User can use this information to understand and analysis the laptop battery status and make
decision on their re-conditioning action base on these parameters.
When the channel is at FINISH state, the information will include the latest SMBus parameters and also the current
test results. User can use this information to generate a report for recording or documentation.
RA-530 will refuse any data retrieval during any other operation states: SET UP and TESTING.
Instant Report:
RA-530 will not store any previous test result in its memory. All test results will be reset once the channel change
from FINISH state to READY state. The information returns only reflect the current test result.
Output Format:
The Instant Report Generation software will automatically generate a testing report; detail of the report format is
shown in Section 6. It also allows the user to save the retrieved information into DOC format file for further data
processing by MS WORDS.