4.
Trouble Shooting
4.1.
Battery LED OFF
After connected the battery pack and connector to a specific channel, the battery Status LED
is OFF:
1.
Check the entry of the battery model name again from the Main Menu, if error in the
entry, re-enter the battery model name;
2.
Check the connector number with the LCD display again, replace a correct connector is
wrong;
3.
Check polarity of the battery with the connector again, re-connect the connector
according to the LCD display;
4.
Check the contacts between the connector and the battery, some batteries have smaller
contact points that some PIN in the connector might not make the full contact.
5.
Battery might entered sleep mode, select waken charge scheme and start the test. The
system will activate a waken charge automatically to recover the sleeping battery.
6.
If waken charge failed, there is not much we can do about the battery, return the battery
for RMA
4.2.
SMBus Read N/A
All values are displayed as N/A when user tried to read SMBus
from the SMBus checking interfaces. The N/A values represent
error is encountered during the read:
1.
Check Channel Battery LED to see if Green is ON, if yes, repeat
the read action again to see if the problem persists. If yes
after repeat reading, select waken charge to recover the
battery.
2.
If the Battery LED RED is ON, it means the polarity of the
connector is wrong, double check the connection direction as
displayed on the LCD screen. Try to reverse the connector to
see if the Green turns ON;
3.
If Battery LED is OFF, repeat checking procedures stated in
Section 4.1
1
Conditioner
Battery
N/ACYC N/AV
N/AmAH N/A%
Cycle
Count
Voltage
RSOC
FCC