Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-P500H
9
The output head is IQB, the following figure 3 show the details of the IQB output
head.
Figure 3 IQB Output head (unit: mm)
CAUTION:
(1)
Keep the protective cap properly, prevent it from
contamination; Or the aperture will be contaminated when
capped.
(2)
Make sure the aperture and the cavity of the processing head is
clean.
3.2
Cooling Requirements
Table 3 Cooling Requirements
Parameter
Unit
Value
Cooling Capability
W
≥2000
Minimum Flow
L/min
8
Maximum Pressure
Bar
8
Water-cooling pipe
connector
mm
Pagoda-Typepipe
connector,outside diameter
12mm
Temperaturesettingof cooling water:25
±
0.5
℃
Requirements on Cooling Water:Purified water should be used.
a)
In order to prevent the growth of mould that may lead to blockage, adding
alcohol solution to about 10% of the total volume is recommended.