The  device  has  three  cooling  fans  at  the  rear  panel  to  dissipate  heat.  In  order  to 

guarantee  enough  airflow  to  help  giving  heat  off,  there  must  be  a  space  of  at  least 

10cm’s width for airflow in front and rear side  of the device. As the cooling fans are 

working  at  blow  condition,  if  laser  is  mounted  in  a  cabinet  with  fans,  the  direction 

should be same as laser’s fans. 

g)

 

Do  not  look  into  the  output  head  of  the  device  directly.  Please  do  wear  appropriate 

laser safety eyewear during the time when operating the device. 

h)

 

Make sure the pulse repetition rate higher than 30 KHz. 

i)

 

For  the  longest  time  without  pulse  is  only  100  us.  If  there  is  no  pulse  output,  please 

stopmarking at once, to avoid further damage of the device. 

j)

 

Power source sudden interruption will do great harm to the laser device. Please make 

sure the power supply works continuously. 

1.4.

 

Specifications 

Table 2. 20QS

30QS pulsed fiber laser specifications 

Pulsed fiber laser 

20QS 

30QS 

Wavelength

nm

 

1060~1085 

1060~1085 

Polarization 

Random 

Random 

Optical isolator 

Yes 

Yes 

Nominal average output power (W) 

≥20 

≥30 

Single pulse energy (mJ) 

0.66@30kHZ 

0.75@40kHZ 

Beam quality

M2

 

<1.6 

<1.6 

Beam Diameter

mm

 

6

6

Pulse duration

ns

 

120-150@30kHZ 

130-160@40kHZ 

Pulse repetition rate

kHz

 

30-60 

40-60 

Output Power Tunability

%

 

10-100 

10-100 

Output Fiber Cable length

m

 

3.0 

3.0 

Working voltage

VDC

 

24±1 

24±1 

Power consumption

20

℃)(

W

 

150 

200 

Cooling 

Forced Air Cooled 

Forced Air Cooled 

Dimension W×D×H

mm

 

290*215*95 

290*215*95 

Operating temperature

(℃)

 

0

℃~

40

 

0

℃~

40

 

Store temperature

(℃)

 

-10

℃~

60

 

-10

℃~

60

 

humidity

%

 

30%~85% 

30%~85% 

Summary of Contents for RFL-P20QS

Page 1: ...内部 A0 会签 阶段 标记 C RFL P20QS 30QS 20QS 30QS 激光器英文说明书 RFL P20QS 30QS JS02 部 门 脉冲激光器技术研究部 编 写 颜鹏晖 20210303 校 对 刘 红 20210305 审 核 李 科 20210305 标 审 李其军 20210305 批 准 黄 保 20210308 武汉锐科光纤激光技术股份有限公司 谢良 夏巨江 旧底图登记 号 底图登记号 ...

Page 2: ...User Instruction RFL P20QS RFL P30QS Wuhan Raycus Fiber Laser Technologies CO Ltd 2021 ...

Page 3: ...r device Before supplying the power to the device please make sure that the correct voltage of 24VDC power source is connected and the anode and cathode are right Failure to connect power source correctly will cause damage to the device b The device emits invisible 1060 1085nm wavelength light with average power 20W 30W Do not expose your eyesor skin to the radiation of the laser c Do not take apa...

Page 4: ...3 Environmental requirements and cautions 1 1 4 Specifications 2 2 Mounting 3 2 1 Mounting dimensions 3 2 2 Method of installation 3 3 Control Interface 4 4 Operation Regulations 6 4 1 Pre inspection 6 4 2 Operation procedures 7 4 3 Cautions 7 5 Instructions for warranty return and maintenance 8 5 1 General warranty 8 5 2 Limitations of warranty 8 5 3 Service and repairs 8 ...

Page 5: ...Items Quantity Remark Fiber Lasermodule 1 1 3 Environmental requirements and cautions Pulsed laser should be driven by 24VDC 1V power source a Caution Make sure the corresponding wires of the device are properly grounded b All the maintenance to the device should only be done by Raycus because there is no replacement or accessory provided with the device Please do not try to damage the labels or o...

Page 6: ...there is no pulse output please stopmarking at once to avoid further damage of the device j Power source sudden interruption will do great harm to the laser device Please make sure the power supply works continuously 1 4 Specifications Table 2 20QS 30QS pulsed fiber laser specifications Pulsed fiber laser 20QS 30QS Wavelength nm 1060 1085 1060 1085 Polarization Random Random Optical isolator Yes Y...

Page 7: ...mensions a Fiber Laser module dimensions As shown in Fig 1 Figure 1 Dimension drawing of laser module Unit mm b Isolated output head dimensions As shown in Fig 2 Figure 2 Dimension drawing of output isolator Unit mm 2 2 Method of installation a Fix the module stable to the bracket and keep the laser in good ventilation ...

Page 8: ...hes the laser and the control cable is well connected to the laser s interface The recommended electrical connection is shown in Fig 4 User s cont rolle r DB25 Controller interface Power supply wire Laser Module 24V Brown L N GND External GND 24V power supply 24V Blue Figure 4 Schematic of recommended electrical connection d The bending radius of the delivery fiber should not less than 15cm 3 Cont...

Page 9: ...ssion Enable EE signal HIGH Emission Enable LOW or disconnected Emission Disable 19 EM Emission Modulation EM input HIGH 3V Emission ON LOW or disconnected 1V Emission OFF 20 Sync Pulse Repetition Rate Synchronization input square wave 22 Guide Laser signal Guide Laser red diode ON OFF input 9 23 Obligate PIN Reserved for Raycus only a The pump current of diode laser and the laser output power are...

Page 10: ... 0 1 1 1 1 PIN 8 1 1 1 1 1 Current 50 75 87 5 93 75 100 Table 5 Definition of alarm status PIN 12 PIN 11 PIN 16 PIN 21 Alarm item Low Low Low Temperature alarm Low Low High Normal Low High High System alarm High Low Low Supply voltage e PIN 10 13 14 15 24 25 are all digital GND f PIN 20 is the pulse repeating rate signal PRR TTL level If the PRR need to be changed during the work it must be change...

Page 11: ...0KHz c Laser marking checking For the device initial testing firstturn the power down to zero without turning on the marking system after the device is successfully started Then draw a quadrate marking continuously whileslowly increasing the power from zero to 100 at the same time Meanwhile use a ceramic material to observe the laser and the laser should become stronger otherwise shut down the dev...

Page 12: ...ages due to excessive use or not following the instructions caused by those who are not from Raycus Customer has the responsibility to understand and follow this instruction to use the device Any damage caused by fault operating is not warranted Accessories and fiber connectors are excluded in this warranty According to the warranty client should write to us within 31days since the defect is disco...

Reviews: