8
5)
Do not look directly into the laser output. Be sure to wear protective glasses when
operating the laser.
Do not expose this product to high humidity
(>
95%
)
Do not let this product work below the ambient dew point temperature.(see
Table 3)
Table 3
The Constant Dew Point Table
AMBIENT DEW POINT
Room
Temperature(℃)
Maximum Relative humidity
20%
30%
40%
50%
60%
70% 80% 90% 95%
20
-3.5
2
6
9
12
14.5 16.5
18
19
25
0.5
6
10.5
14
16.5
19
21
23
24
30
4.6
10.5
15
18.5
21.5
24
26
28
29
35
8.5
15
19.5
23
26
28.5
31
33
34
40
13
20
24
27.5
31
33.5
36
38
39
Laser operating temperature range
Green area: The dew point temperature is
22℃
that is lower than the laser
cooling water temperature, which can be used safely
;
Red area: If the dew point temperature is higher than
22℃
and exceeds the
laser cooling water temperature by
22℃
, there must bedew condensation,
and measures must be taken.
Measure 1: Dehumidifier works for 10-15 minutes in standby mode(laser
power and cooling water should be on state );
Measure 2: Installing cabinet air conditioner to reduce ambient
temperature.
2.5 Precautions for Use
1)
Before supplying the power to the device, make sure that the correct voltage of the AC
power source is used. Failure to connect power source correctly will damage the device;