Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C6000S-CE
53
Low temperature alarm, please check if the actual water temperature of the
water is too low. In addition, a low ambient temperature may also cause a low
temperature alarm when the laser is cold. Please wait until the water
temperature of the water rises above 10°C.
Laser Water flow
Instruction:
The water flow rate of the laser alarms. The current water flow rate detected
inside the laser is lower than the required value, and there is a safety risk.
Solution:
Stop using the laser immediately.Please check the output model and working
status of the laser water cooler and clean the laser water filter module
according to the laser operation requirements in
the section 3.3 cooling
System Installation and Requirements
.It is recommended to clean the water
cooler and the water inlet filter assembly regularly, and replace the cooling
water.
Scattered Light
Alarm
Instruction:
Scattering light alarm, when the intensity of ambient light inside the laser
exceeds the set value, the scattering light alarm will be generated, and the laser
emission function will be locked (cannot be unlocked).The scattered light
alarm only occurs when the laser emission.
Solution:
Please restart the laser,
check the guide laser state of the laser, and through the
clientware "from the control module" reading the scattered light monitoring
voltage value,
and contact Raycus.
Laser Power Alarm
Instruction:
The alarm is generated when the emission of the laser cannot reach the set
value. Power error occurs only when the laser is emitting.
Solution:
Please restart the laser,
check the red light state of the laser
,and contact
Raycus.
AC DC Alarm
Instruction:
AC DC Error, failure ofthe laser power supply or sudden power failure of the
power supply system may cause an alarm.
Solution:
Check if the input AC voltage is normal. Restart the laser, if this error
continues to occur, please contact Raycus.
Current Driver
Alarm
Instruction:
Current Driver Alarm,this error occurs when the constant current driver board
inside the laser is abnormal.
Solution: