Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C6000S-CE
23
Passive contact, not
connected to external
voltage or grounding.
9
RPB
10
Remote Start
Button
START-
A
Instantaneou
s Contact
Closure
Input
24Vdc
---
1s
In REM mode, start
the laser main power
supply.Passive
contact, not connected
to external voltage or
grounding.
11
START-B
12
Analog Input
to Control
Current
1-10V
Analog Input
1-10
Vdc
10 mA
100µs
Analog Input 1-10
VDC= 10 – 100%
Setpoint
13
Analog Output
Power Monitor
AOUT
Analog
Output
0-8.0
Vdc
>5mA
20µs
Analog Output
0-8VDC
(
Refer to
factory inspection
report for details
)
14
Isolated
Analog Com
AGND
Return
---
---
---
Return for signals on
pins 12, 13
15
Mod
MOD+
Digital Input
24V
d
C
<10
mA
20µs
24 VDC Input
16
Modulation-
MOD-
Return
---
---
---
Return for signal on pin
15
17
Guided Laser
Control
RED-LAS
ER
Digital Input 5-24Vdc
<10
mA
120ms
Positive edge activates
emission in REM mode
18
Emission
Enable
LAS-C
Digital Input
5-24Vd
C
<10
mA
120ms
Positive edge activates
emission in REM mode
19
READY
READY
Digital output 24VdC
>
10mA
120ms
High=Laser is ready
20
System
Common
GND2
Return
---
---
---
Return for pin
17/18/19/21/22/23/24
21
Error RESET
RESET
Digital Input
5-24Vd
C
<10
mA
120ms
Rising edge reset (the
resettable alarm)
22
Laser Alarm
S-ERR
Digital output 24VdC
>
10mA
120ms
High=Alarm status
23
Power started
POWER
Digital output 24VdC
>
10mA
120ms
High= The main power
supply is started
24 Laser emission
LASER
Digital output 24VdC >10mA 100ms High=Laser is emission