Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C20000TZ
40
6.5. Set the Power Analog Quantity in REM Mode to Control the Laser Emission
Figure 22 REM mode power and laser emission are externally controlled wiring diagram
Operations Steps
a) Turn the knob switch on the rear panel to“ON”
b) Turn the key switch to“REM”
c) Short-circuit pin 8/9 on XP2
d) XP1-A1 connects to 24V, XP1-A6 connects to 24V
e) Connect XP1-A5 to 24V and turn on the guide laser; after checking the optics, connect XP1-A5
to 0V and turn off the guide laser
f) XP1-C1 is connected to 24V, and the main power is turned on (operator can also directly press
the LASER button, or the host computer software clicks the main power “ON”);
g) Waiting for “Ready”;
h) XP1-A2 connects to 24V, and the control board outputs analog and MOD signals