Page 1: ...RAYCUS RFL C1500H...
Page 2: ...Attentions 11 2 7 Specifications 12 3 Installation 12 3 1 Dimensions 13 3 1 1 Overall dimensions of RFL C1500 cutting laser 13 3 2 Size and installation of output optical cable 14 3 2 1 RFL C1500 Outp...
Page 3: ...ect 4 6 in sequence 31 4 7 3 External control mode sequentially connected to 4 6 32 4 7 4 AD Mode 33 4 7 5 Controlling time series chart 35 4 7 6 Red Light Control 35 4 8Turning off the laser 36 5 Com...
Page 4: ...l injury or death CAUTION Describes a hazard that leads to a minor personal injury or product damage 1 2 Laser Safety Grade This series of lasers are classified as a high power Class 4 laser instrumen...
Page 5: ...e range of laser wavelengths Please do not directly look at the fiber delivery cable connector when laser is powered on 1 3 Security Identifiers Raycus CW Fiber Lasers have different locations of safe...
Page 6: ...the end of the collimator assembly can burn the lens CAUTION DO NOT emit laser when the protective cap is not removed otherwise the lens or crystal will be damaged 1 5 Electrical Safety 1 Make sure th...
Page 7: ...nment 3 If this device is used in a manner not specified in this document the protection provided by the device may be impaired and the warranty will be voided 4 There are no user serviceable parts eq...
Page 8: ...ti reflection Capacity High modulation frequency and editable waveform Applications Welding 5G Infrastructure 3D printing Laser research 2 2 Model description Raycus continuous wave laser includes 100...
Page 9: ...imal safety Nevertheless in order to prevent the occurrence of unpredictable circumstances during the transportation please inspect all packaging once receiving the delivery If you find any evidence o...
Page 10: ...acity kW 5 5 Installation Environment Flat and no vibration Ambient Temperature 10 40 Relative Humidity 70 Warning 1 Make sure the product is properly grounded before use 2 The laser output head is co...
Page 11: ...1 23 24 30 4 6 10 5 15 18 5 21 5 24 26 28 29 35 8 5 15 19 5 23 26 28 5 31 33 34 40 13 20 24 27 5 31 33 5 36 38 39 Laser operating temperature range 2 6 Attentions 1 Make sure that the correct voltage...
Page 12: ...ntTemp 25 ModulationFrequency Hz 50 20 000 NominalOutputPower RedGuideLaserPower mW 0 1 1 OpticalOutputCharacteristicsofQBHhead BeamQuality M NominalOutputPower CoreFiber m 50 14 20 100 200 are option...
Page 13: ...r 3 Installation 3 1 Dimensions 3 1 1 Overall dimensions of RFL C1500 cutting laser The front and rear panel sizes of the small volume 1500W continuous laser are same as the RFL C1000 laser as show in...
Page 14: ...6 in the chart 3 2 Size and installation of output optical cable Raycus continuous wave fiber laser uses different laser output cables according to different laser models 3 2 1 RFL C1500 Output Optica...
Page 15: ...er the output fiber cable is installed in the processing equipment Before installing the output cable in the processing head the lens of the output cable must be inspected If the lens is dirty it must...
Page 16: ...it every 2 months If ambient temperature is below 10 the chiller with both heating and cooling functions must be used and keep it in full time operation 3 Other cooling system requirements Check the e...
Page 17: ...immobilize it if necessary 2 Check if the power supply has the correct voltage laser model and power voltage refers to product parameters in Table 5 and the earth line is connected and ensure the ear...
Page 18: ...tate such as transport and storage The minimum bending diameter should not be less than 30cm when the laser is working CAUTION All the cables can only be connected when power supply is off Hot plug ma...
Page 19: ...icial website of Raycus to download the new version of the upper computer software and upper computer software instruction manual Web http www raycuslaser com index php index show tid 53 html 4 1 Fron...
Page 20: ...rt the quick plug water pipe with an outer diameter of 16 into the pagoda head and fasten it with a clamp to connect the laser to the circulating cooling water 5 Interface Laser external control inter...
Page 21: ...RFL C1500 Power supply 220 10 V AC 50 60Hz Power cord Power cord end Three strands marked L N and PE respectively Label description L Phase line brown N Neutral blue PE Protective earth wire yellow gr...
Page 22: ...nt 2 Reserve interlock Short circuit 3 Reserve interlock 8 Reserve long dista nce power supply Short circuit 9 Reserve long dista nce power supply 10 Reserve emergency stop Short circuit 12 Analog Ana...
Page 23: ...10mA 22 Laser Error Digital output Laser fault output signal EVCC 100mA 23 EVCC Digital input External voltage for output of Ready and Error signals 5 24V 5V 24V 100mA other NC Not allowed to connect...
Page 24: ...For specific commands and descriptions please refer to the software manual of the host computer or ask a Raycus technician for a communication protocol The specific parameter settings of the RS 232 c...
Page 25: ...n The laser listens for connections on port 8099 The command must be sent as a single string in a single packet Table 11 Ethernet interface pin definition PIN Feature Description 1 TX Transmit Data 2...
Page 26: ...tware of Raycus to control the laser you need to find the folder where the upper computer software is located open the laser configuration file config xml and write the newly set IP address of the las...
Page 27: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of 1500W CW laser 27...
Page 28: ...position to fix it with screws 2 Remove the protection cap of the output head use strong light to check if there is dust on the lens of the output end If so please clean it before use and then cover...
Page 29: ...the rocker switch is off All electrical connections must be completed before the laser is powered on 1 Turn on the chiller and check the water pipe for leaks If there is no leakage turn off the chille...
Page 30: ...ing diagram Figure 11 Wiring diagram in RS 232 mode Note In the above mode the upper computer of Raycus should be used to modify the mode turn off the external red light control external light out ena...
Page 31: ...it initialization is completed 3 Turn off all external control mode of the laser turn off external control of red laser external light emitting enable external AD and modulation mode 4 Set the power o...
Page 32: ...trolled by the modulation signal provided by the user from the external MOD interface For the timing diagram see 4 7 5 Control timing Figure Gate mode When the duty cycle of the laser s internal frequ...
Page 33: ...ace to issue the shutter open command enable light 9 The On Off of the laser is controlled by the modulation signal provided by the external mod interface Shutdown the laser please refer to 4 8 4 7 4...
Page 34: ...ycus Fiber Laser Technologies Co Ltd User Guide of 1500W CW laser 4 7 5 Controlling time series chart Figure 13 Standalone mode Continuous sequence diagram Figure 14 Standalone mode Pluse sequence dia...
Page 35: ...7 6 Red Light Control Turn on the rocker switch the green POWER indicator light is on wait for 20s the laser enters the red light external control mode and a high level of 5 24V is given before the 17...
Page 36: ...he laser Please turn off the laser in the following sequence 1 Turn off the laser output enable 2 Turn off the rocker switch 3 Turn off the chiller 4 If the laser is not equipped with air conditioner...
Page 37: ...ent software interface as shown in Figure 17 The laser will give an alarm in the case of abnormal internal temperature abnormal output power abnormal power supply abnormal condensation etc Figure 17 m...
Page 38: ...panel of the laser has been pressed before powering on Solutions When this alarm occurs please power off the laser and make the light enable button pop up and then power on the laser again to cancel t...
Page 39: ...he laser is emitting light Solutions Restart the Device If this error continues to occur please contact Raycus ACDC1 Alarm Instruction AC DC1 Alarm Laser power supply out of work or sudden power disco...
Page 40: ...ctual water temperature of the water is too low In addition a low ambient temperature may also cause a low temperature alarm when the laser is cold Please wait until the water temperature of the water...
Page 41: ...under warranty Raycus reserves the right to issue a credit note for any defective products produced in normal conditions 6 2 Limitations of Warranty The warranty does not cover the maintenance or rei...
Page 42: ...cus personnel Please contact Raycus as soon as possible when problems under warranty about maintenance happened to the product The product returned with permission should be placed in a suitable conta...
Page 43: ...www purelogic ru 7 495 505 63 74 7 473 204 51 56 394033 160 149 info purelogic ru 8 800 555 63 74 800 1700 800 1600...