f) XP1-C1 is connected to 24V, and the main power is turned on (you can also press the LASER
button directly, or the upper computer software points the main power ON).
g) wait for the green light of the laser tricolor lamp to light up, the laser preparation work is
completed.
h) The software of the upper computer sets the light output power, XP1-A2 connects to 24V and
controls the board MOD signal.
I) Check the laser tricolor lamp red light is on and the laser is outputting light.
6.7 Programming mode in REM mode
Figure 26 Wiring diagram of programming mode on REM mode.
Operation methods:
a) The rear panel air switch hits ON to supply power to the laser.
b) Front panel key switch to REM, the laser into REM mode;