background image

Wuhan Raycus Fiber Laser Technologies Co., Ltd.

User Guide of RFL-A6000D~10000D

30

B10

Programming

mode execution

completed

Output signal

Output signal, indicating that the laser

programming mode is completed, the bit clears

when the A2 is invalid

B11

Abnormal Wave

Mode

Termination

Output signal

output signal indicating that the laser

programming mode is abnormally terminated

RESET (a4) cleared

B12

Synchronous

output

Output signal

Output signal, high effective, low invalid

B13

Warning output

Output signal

Output signal, indicating a warning to the laser

B14

Backup

B15

External power

supply

positive

The external 24 V input voltage, all table output

signal power supply, only these two feet access

24 V power output signal is effective

B16

Negative external

power

D1

D4

Current gate

channel

indication

Output signal

Output signal indicating the actual channel position of

the current gate.

0000-gate closed, channel 0001-1

selected, channel 0010-2 selected, channel
0011-3 selected (Open only to lasers with gate
pairs, other lasers this pin standby)

D5

Water cooler

warning

output

Output signal

Current water temperature warning

D6

Water cooler

alarm output Output signal

Current water temperature alarm

D7

Back up

D8

D11

Laser hardware

address

Output signal

Coding-Cable function ;0000-0 laser ,0001-1 laser;

D8 low, D11 high

Summary of Contents for A10000D

Page 1: ...RFL A6000D 10000D Fiber Delivered Direct Diode Lasers User Guide Wuhan Raycus Fiber Laser Technologies Co Ltd ...

Page 2: ... 3 UNPACKING AND INSPECTION 4 2 4 OPERATION ENVIRONMENT 5 2 5 ATTENTIONS 5 2 6 SPECIFICATIONS 6 3 INSTALLATION 7 3 1 DIMENSIONS 7 3 2 INSTALLATION RULE 10 3 3 COOLING REQUIREMENTS 13 4 USING THE PRODUCT 15 4 1 FRONT PANEL 15 4 2 REAR PANEL 16 4 3 POWER CONNECTION 17 4 4 CONTROL INTERFACE DEFINITION 19 4 4 1 Safety XP2 Interface 21 4 4 2 Hard Wiring XP1 27 4 4 3 RS232 XP3 Interface 30 4 4 4 Analog ...

Page 3: ...8 6 1 INTERNAL CONTROL IN ON MODE 38 6 2 EMISSION EXTERNAL CONTROL MODE SET BY POWER COMMUNICATION IN ON MODE 39 6 3 EMISSION EXTERNAL CONTROL SET BY POWER ANALOG IN ON MODE 40 6 4 EMISSION EXTERNAL CONTROL THROUGH PROGRAMMING MODE ON THE ON MODE 41 6 5 SET THE POWER ANALOG AS EMISSION EXTERNAL CONTROL ON THE REM MODE 43 6 6 REM MODE POWER COMMUNICATION SET OUT LIGHT EXTERNAL CONTROL 44 6 7 PROGRA...

Page 4: ...TING MODE SELECTION 62 8 7 LANGUAGE 64 8 8 AUTHORIZATION TIME LIMITED LOCKING 64 8 8 1 Authorization on user mode 64 8 8 2 Authorization on authorization mode 65 8 9 ABOUT 66 8 10 XP1 INTERFACE STATUS INDICATION IN DIAGNOSTIC MODE 67 8 11 LOG IN DIAGNOSTIC MODE 68 8 11 1 Download log 69 8 11 2 Downloadrecord of historicalfault 70 8 11 3 Downloaded file address 70 8 12 MODULE PARAMETERS IN DIAGNOST...

Page 5: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of RFL A6000D 10000D 9 2 LIMITATIONS OF WARRANTY 79 9 3 SERVICE AND REPAIR 79 ...

Page 6: ...ollowing cautions and warnings as well as other information within this manual 1 1 Security Labels WARNING Describes a hazard that leads to severe personal injury or death CAUTION Describes a hazard that leads to general personal injury or damages to product English Label Chinese Label English Label 6000W Chinese Label 6000W English Label Chinese Label 1 Fiber Delivery Cable Connector 2 Type 4 Las...

Page 7: ...es must be worn whenever the laser is emitting WARNING Users must use appropriate laser goggles when operating this device The laser goggles are selected according to the range of wavelength emitted from this product Users must select the appropriate laser goggles according to the entire range of laser wavelengths Please do not directly view whether the laser Is emitting or not the laser output he...

Page 8: ...ified in this manual the protection provided by the device may be impaired and the warranty will be voided d There are no user serviceable parts equipment or assemblies inside the product All service and maintenance shall be conducted by a certified Raycus engineer In order to prevent electric shock please do not break the seal or uncover the shield Otherwise any damage to the device will not be g...

Page 9: ...t unpredictable situations during transportation the users still need to carefully check whether the package is correctly placed before unpacking and there is no damage from phenomenon such as collision cracking and flooding on the outside of the box Once you find that there is an abnormality in the external cabinet please inform Raycus Company in time to deal with it as soon as possible Please do...

Page 10: ...pply capacity kVA 20 25 32 Installation Environment Flat no vibration nor impact Ambient Temperature 10 40 Relative Humidity 70 Tips Install the laser in an air conditioned environment for longer life and better performance 2 5 Attentions a Make sure the product is properly grounded before use b Make sure that the correct voltage of 380VAC is used Power supply connection failures will cause irreve...

Page 11: ...nter can cause the laser s internal cooling water to freeze easily causing permanent damage to the laser please ensure that when the laser is in the shutdown state the water cooler continuous operation h Failure to follow the instructions above may cause laser power loss and such loss is not covered by warranty 2 6 Specifications Table 2 Product Specifications Optical properties Test Conditions Mo...

Page 12: ...Customizable Electrical characteristic Operating Voltage Three phase four wire system AC323V AC437V 50 60Hz Include PE Maximum power Consumption kW 15 20 25 Nominal Output power Way to control RS232 Serial communication AD Other characteristic Dimension mm 897 1159 96 8 1199 1159 968 Includes casters and rings without warning lights Weight kg 360 400 450 Air conditioning included Operating Ambient...

Page 13: ...3 Installation 3 1 Dimensions The main body dimensions of RFL A6000D fiber delivered direct diode laser shown in Figure 1 Figure 1 a Front and rear view of the laser Figure 1 b Top and left view of the laser Figure 1 the dimensions of RFL A6000D fiber delivered direct diode laser ...

Page 14: ...rect diode laser uses RFL iHQB fiber delivery cable and its form factor is shown in Figure 2 Figure 2 External dimensions of the RFL HPQ fiber delivery cable connector RFL A8000D A10000D The main body dimensions of RFL A6000D fiber delivered direct diode laser shown in Figure 3 a Front and rear view of the laser ...

Page 15: ... QD fiber delivery cable connector Note The dimensions in the above diagram are in the unit of mm Before the laser works make sure that the two copper contacts Interlock pins on the fiber delivery cable connector are shorted otherwise the laser will not work properly Before installing the output cable into the processing head the lens of the output cable must be inspected If the output cable lens ...

Page 16: ...delivery cable connector to avoid damage to the optical fiber g In the process of installing the optical cable output head ensure the cleanliness of the surrounding environment do not use electric fans to dissipate heat when it is hot in summer to avoid large dust in the air h The minimum bending diameter of the laser transmission cable in non working conditions such as transportation and storage ...

Page 17: ...AUTION All the cables can only be connected when power supply is off Hot plug may damage the device CAUTION 1 The placement of the laser output cable should be as natural as possible and the output cable should not be twisted 2 If the coil diameter of the fiber delivery cable connector is too small it will damage the laser Lifting ring Lifting ring Leveling casters Leveling casters ...

Page 18: ... 25 0 5 Requirements of Cooling Water a Cooling water needs to be pure water b In order to prevent the water in the water cooler from growing mold and causing pipeline blockage it is recommended to add alcohol when filling pure water and the amount of alcohol added is 10 of pure water c When the ambient temperature of the equipment is between 10 and 0 the glycol solution with a volume ratio of 30 ...

Page 19: ...e a month h Maximum cooling water temperature 35 i The lowest cooling water temperature 5 greater than the saturated dew point temperature j Additives in cooling water meet the above PH value and solid particle size requirements Other requirements a When starting the cooling system for the first time check the entire water system and joint for water leakage b If the laser is not used for a long ti...

Page 20: ...he PC software user manual Website http www raycuslaser com 4 1 Front Panel Figure 6 shows the front panel Figure 6 Front view of the panel REM OFF ON The key switch is the main control switch of the laser Insert the key and turn it to the ON position the main control part of the laser is powered on and the POWER light is on Rotate to the REM position you need to close the Pin8 and Pin9 of the XP1...

Page 21: ...ng the power on self check on the control panel After the self inspection is completed all INTERLOCK interfaces are normally closed and the ALARM indicator is off During the operation of the laser any INTERLOCK failure will cause the indicator to light STOP Emergency stop button press it to turn off the laser immediately turn clockwise to release the button Use the key to turn on the laser and pow...

Page 22: ...ncluding RS232 communication laser on off control laser remote control mode selection analog control modulation signal Interlock interface etc Refer to Table 4 for the definition of control lines This socket comes with a protective cover and a lock When you are not using the product you can cover the power input socket with the protective cover and lock it with the lock ...

Page 23: ...TER IN The water inlet of the laser this interface is connected to the water outlet of the cooling water of the water cooler Filter filter the cooling water into the laser WATER OUT The water outlet of the laser this interface is connected to the water inlet of the cooling water of the water cooler 4 3 Power Connection CAUTION 1 Before connecting to the AC power supply please check whether the sup...

Page 24: ...ket as shown in Figure 9 Figure 9 physical picture of power cord plugs and socket The laser AC input line uses a 4 core cable and its AC input line interface definition and parameter requirements are shown in Table 4 Table 4 AC input line interface definition and parameter requirements 6kW laser AC input line interface definition and parameter requirements Connector Tag Interface definition Logo W...

Page 25: ...nector tag Interface definition Logo Wire diameter wire color Wire length 1 2 AC380V L1 L1 6mm2 6m m2 Brown 15m 3 4 AC380V L2 L2 6mm2 6m m2 Black 15m 5 6 AC380V L3 L3 6mm2 6m m2 Grey 15m PE protective PE 6mm2 Yellow green 15m 4 4 Control Interface Definition This type of laser does not provide a control signal line only a control signal connector The appearance of the joint is shown in Figure 10 ...

Page 26: ...ote main power power on and active and passive output of some lasers The detailed interface definition is shown in Table 5 Table 5 XP2 security interface definition Pin Number Type Description 1 MOD Output control voltage input signal laser ON 4 30V Laser OFF 3 2V Highest frequency 2kHz 2 MOD HARDWIRING XP1 Security interface XP2 Analog interface XP4 Serial interface XP3 Communication Interface XP...

Page 27: ...he current panel stop press 11 14 open or short circuit 14 OUT 12 OUT Front panel emergency output 2 relay contact output passive contact current 100 mA voltage 30V The current panel stop press 12 13 open or short circuit 13 OUT 15 OUT FET S pole Main power supply power on output indication MOS pipe D S output current 0 5A voltage 30V passive signal 16 OUT FET D pole 17 IN Interlock1 import Active...

Page 28: ...o control the laser output and off when the key switch is hit ON and t he laser is working out of light external control mode When the key switch hits REM and the laser is operating in outgoing light control mode MOD and XP1 A2 at this time the A2 bit outgoing light enable signal are jointly used to control the laser output and off in REM mode outgoing light control can be controlled only by A2 to...

Page 29: ...red on output indication The internal circuit diagram is shown in Figure 12 and the recommended customer wiring diagrams are shown in Figures 13 and 14 Figure 11 Out light output and main power up indication circuit diagram Figure 12 Recommended wiring diagram for light output indication 12V as an example Customer 12v positive power supply Customer 12v negative power supply PIN PIN Indicator light...

Page 30: ...tion and main power supply has been powered on warning indication the internal circuit diagram is shown in Figure 15 and the recommended customer wiring diagram is shown in Figure 16 Figure 14 Active light out indication and main power supply has been powered on indication circuit diagram Customer 12v positive power supply Customer 12v negative power supply PIN PIN Indicator light 12V for example ...

Page 31: ...pply has been powered on the recommended wiring diagram d The recommended customer wiring diagram for the remote master board power up is shown in Figure 16 Figure 16 Remote control board power up recommended wiring diagram PIN PIN PIN PIN PIN PIN 24V light output indicator 24V Main power supply online indicator light ON OFF switch ...

Page 32: ...ay output the main control board power on the relay suction 4 4 2 Hard Wiring XP1 64 pin hard wire interface control signal input and output interface of laser in remote mode Input high level is greater than 18V valid input low level is less than 3V valid Specific interface definitions are shown in Table 6 below Table 6 XP1 Hardwire interface definitions No XP1 Interface requirements type descript...

Page 33: ...patterns Input signal High level enables PC software control function A4 Reset signal Input signal High level effective clear laser alarm bit effective high level time at least 1 MS A5 Red light indicator Input signal The effective red light indicates light A6 Simulation control enabling energy Input signal The input signal can simulate the input signal Program num 0000000 A7 Stop programming Mode...

Page 34: ... mode B4 Laser anomalies Output signal Output signal indicating Abnormal laser B5 Laser red light indication Output signal Output signal indicating that the laser is red B6 AD mode Output signal Output signal indicating that the laser operates in AD mode B7 Laser received request signal Output signal Output signal indicating that the laser receives a request signal A1 B8 Main power supply in laser...

Page 35: ...Backup B15 External power supply positive The external 24 V input voltage all table output signal power supply only these two feet access 24 V power output signal is effective B16 Negative external power D1 D4 Current gate channel indication Output signal Output signal indicating the actual channel position of the current gate 0000 gate closed channel 0001 1 selected channel 0010 2 selected channe...

Page 36: ... Laser 5 COM GND Serial port public end 4 4 4 Analog Interface XP4 The analog interface an 8 core Harting interface is used to control the output power of the laser by analog in AD mode and can also monitor the output light and power feedback signals of the laser The interface definition is shown in Table 8 below Table 8 XP4 Analog interface definitions Pin No type description 1 IN 0 10 V analog s...

Page 37: ...be turned on When one of the channels is open the laser main power supply is impossible to start until the other channel is open and then the two channels are closed before the laser main power supply can be started If the interlock is closed the stop button is also released and there is no error alarm press the start LASER button to start the main power supply and the main power has been started ...

Page 38: ...ure 19 Schematic diagram of the internal electrical circuit of the laser 4 7 Start operation sequence a Turn on the water cooler check whether the water pipe is leaking turn off the water cooler and connect electrically b Make sure the circuit breaker is in an OFF state and the stop button on the front panel of the laser EMERGENCY STOP pressed all electrical connections must be completed before th...

Page 39: ...all interlock interfaces have been closed e Select the required control mode according to 1 4 control mode turn on the key switch and start the main power supply waiting for the laser to Ready When the laser Ready the green light comes in the tricolor above the machine representing that the laser can light 5 Control Mode Selection Raycus high power continuous wave laser has two control modes respe...

Page 40: ...ble enable determined by programming command XP1 A1 laser request is high XP1 A2 high level indicates operating programs XP1 A1 A5is high level 1 Communication sends DEC or computer software clicks button 2 Communication sends DLE or computer software clicks button 3 Communication sends EEC or computer software clicks button 4 Communication sends ELE or computer software clicks button 5 XP1 A1is h...

Page 41: ...entage XX represents the power percentage or the computer software clicks button 5 1 ON Mode In the ON mode the user can send commands to set different working modes through computer software or direct communication After the laser is powered on again the mode before power failure will be memorized 5 2 AD Enable Mode When AD mode is enabled the laser power is determined by the analog voltage of pi...

Page 42: ...gramming Mode In the ON mode when the current program number of the laser is not 0 the laser will run in the programming mode Please use the computer software of Raycus to edit the wave and select the pre operation program number When the laser is in the emission internal control mode press or send EMON command the laser starts to operate program send or press EMOFF the laser can stop program at a...

Page 43: ...ght internal control mode and the red light is controlled by the computer software red light button or communication to send ABN and ABF used to control the ON and OFF of the red light When A1 of xP1 is set high A3 is suspended or set low the laser is in external control mode and the red light is controlled by A5 of xP1 The red light module in the laser works by means of communication so there is ...

Page 44: ...ware d Hit the red ON button to view the red light e Turn off the AD mode turn off the external control mode this mode can be remembered when the power is off f Click the main power ON button in the upper computer software to turn on the main power g Wait for the laser tricolor light green light on the laser ready to work completed h Set the light output parameters I Click the ON button in the sof...

Page 45: ... to put the laser into ON mode c Open the upper computer software d Click the red ON button to view the red light e turn off the AD mode open the external control mode this mode can be remembered when the power is off f click the main power ON button in the upper computer software to turn on the main power g wait for the laser tricolor light green light to light up the laser preparation work is co...

Page 46: ... air switch hits ON to supply power to the laser b The front panel key switch is turned ON to put the laser into ON mode c Open the upper computer software d Hit the red ON button to view the red light e open AD mode open external control mode this mode can be remembered when power is lost f click the main power ON button in the upper computer software to turn on the main power g wait for the lase...

Page 47: ...ontrol through programming mode on the ON mode Figure 28 Wiring diagram of Emission external control through programming mode on the ON mode Operation methods a The rear panel air switch hits ON to supply power to the laser b The front panel key switch is turned ON to put the laser into ON mode c Open the upper computer software d Click the red ON button to view the red light e Click the main powe...

Page 48: ...sing edge of the external MOD signal I Check that the red light of the laser tricolor lamp is on and the laser is outputting light Note high level time of MOD must be more than program operation if MOD gives the falling edge in advance the computer software will show that the laser program is stopped abnormally 6 5 Set the power analog as emission external control on the REM mode Figure 23 Wiring ...

Page 49: ... the red light after checking the optics XP1 A5 is connected to 0V to turn off the red light f XP1 C1 is connected to 24V and the main power is turned on you can also press the LASER button directly or the upper computer software points the main power ON g Wait for the green light of the laser tricolor lamp to light up and the laser preparation work is completed h XP1 A2 is connected to 24V and th...

Page 50: ...sion external control on REM mode operation methods a The rear panel air switch hits ON to supply power to the laser b Front panel key switch to REM the laser into REM mode c Shorting pin 8 and pin 9 on XP2 to supply power to the main control board d XP1 A1 is connected to 24V e XP1 A5 is connected to 24V to turn on the red light XP1 A5 is connected to 0V to turn off the red light after checking t...

Page 51: ...r lamp to light up the laser preparation work is completed h The software of the upper computer sets the light output power XP1 A2 connects to 24V and controls the board MOD signal I Check the laser tricolor lamp red light is on and the laser is outputting light 6 7 Programming mode in REM mode Figure 26 Wiring diagram of programming mode on REM mode Operation methods a The rear panel air switch h...

Page 52: ...directly or the upper computer software points the main power ON g Wait for the laser tricolor light to turn on green the laser preparation is completed h XP1 A8 14 select the pre executed program number XP1 A2 set to high to start the execution of the program I Check that the laser tricolor red light is on and the laser is outputting light Figure 27 Timing diagram of control signal of programming...

Page 53: ... this product is not case sensitive To facilitate identification add a space between the command and the parameter d This product sends a return value for each command received The return value generally contains the command content itself If the returned content contains a numeric value or contains an error type the returned command content is separated from the numeric value or from the error ty...

Page 54: ...urn EMOFF r EM ON Start Emission Send EMON r Return EMON r MPWR OFF Main Power OFF Send MPWROFF r Return MPWROFF r MPWR ON Main Power ON Send MPWRON r Return MPWRON r SPW Set Pulse Width Send SPW 100 r Return SPW 100 r Set pulse width as 100ms Other return values ERR input Err r Input pulse width 0 0001 ERR Out of Range r Over maximum pulse width ERR Duty Cycle too High r SPRR Set Pulse Repetition...

Page 55: ...ent set value is 56 7 RPRR Read Pulse Repetition Rate Hz Send RPRR r Return RPRR 10 r Repeat frequency is10Hz RBT Read Board Temperature Send RBT r Return RBT 36 6 r RPW Read Pulse Width MS Send RPW r Return RPW 5 5 r pulse width is 5 5ms RCT Read Laser Temperature Send RCT r Return RCT 34 5 r PERR Reset Errors Send PERR r Return PERR r SUT Set Up Time MS Send SUT 50 r Return SUT 50 r SDT Set Down...

Page 56: ...f 32 Bit digital information The meaning of each Bit is as follows undefined or reserved Bit negligible Send STA Return STA 4100 returned value 4100 Decimal can be converted to 0 x1004 hexadecimal and then converted to binary to see that Bits2 and 12 have been set The laser enable is on and the modulation mode is enabled Bit 0 Normal operation Authorization time Bit 1 Normal Temperature too high B...

Page 57: ...king Bit 14 Normal Leakage sensors 2 leaking Bit 15 No laser Laser is power on Bit 16 Gate mode off Gate mode on Bit 17 AC input normal AC input abnormal Bit 18 External Emission control off External Emission control on Bit 19 Normal Laser fault Bit 20 Slow up slow down mode off Slow up slow down mode on Bit 21 A laser operates in ON mode A laser operates in REM mode Bit 22 Wave mode off Wave mode...

Page 58: ...t External Control Bit 28 normal Water flowmeter 2 Flow Alarm Bit 29 normal Module locked Bit 30 Optical circuit safety interlock normal Optical circuit safety interlock abnormal Bit 31 normal High average power 8 PC Software Instructions PC software downloads address http www raycuslaser com list 56 html 8 1 Main interface of PC software The PC software s main interface is shown in Figure 29 ...

Page 59: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of RFL A6000D 10000D 54 Figure 29 PC software display main interface 8 2 Multi laser Control Area Multi laser control area is shown in Figure 30 ...

Page 60: ...selected laser After the communication established the lower left status display shows that the network connection is ok shown in Figure 31 Figure 31 communication status interface between PC software and laser 8 2 1 Add delete laser You can add delete laser in the laser list area by right click to add delete In the PC software You need to type the IP address of laser to add a new laser Detailed o...

Page 61: ...d User Guide of RFL A6000D 10000D 56 Figure 32 Procedure for adding a laser to the PC software 8 2 2 Modify laser IP After the laser connection has been established select the IP address of current laser and right click to set it up in Figure 33 ...

Page 62: ...ycus Fiber Laser Technologies Co Ltd User Guide of RFL A6000D 10000D 57 Figure 32 Modify the IP address of laser 8 3 Main working status display The laser s main status display is as shown in Figure 34 Table 12 ...

Page 63: ...off Ready light Indicates readiness of current laser green laser is ready gray laser is not ready Alarm light indicates alarm status of current laser yellow laser is abnormal gray laser is normal Emission light indicates the working model of the current laser red laser is in working model gray laser is not in output model 8 3 1 Laser s cumulative operating time display area The laser s cumulative ...

Page 64: ... works in external control mode Gray laser works in internal control mode Laser on off is controllable by software Power correction Green Laser operates in power linear correction mode in which control system automatically adjusts the laser s output power It makes the output power linear with a longer response time for AD analog in this mode longer than 1mS Gray laser operates in non correction mo...

Page 65: ...ode selection light out control display area is as in Figure 37 the display content is as in Table 14 Figure 37 Laser power on mode selection light out control display area Table 14 Laser power on mode selection light out control display area explanation Display content Explanation Main power button Click ON main power on click OFF main power off External control mode Click ON activate laser exter...

Page 66: ...e This function can only run internal mode when external mode is turned off Enter the current pre tested programming number in the digital text box and click the START button Figure 38 Laser programming mode test area display interface 8 3 5 Power slow rise down parameter setting area The interface of the laser power slow rise fall parameter setting area is shown in Figure 39 Click read parameter ...

Page 67: ...hown in Figure 40 The output parameter setting is not valid when AD mode is on Figure 40 Laser output parameter setting area display interface 8 4 Laser parameter display area The display interface for laser parameter display area is shown in Figure 41 The module status is used to shield the faulty module the green light indicates the number of modules installed inside the current laser and the ch...

Page 68: ...e 42 This interface shows the cause of the alarm for the current laser Figure 42 Laser alarm type display area interface 8 6 PC software operating mode selection The laser operating mode is set by the PC software Its operating interface is show in Figure 43 The interpretation of the various patterns can be found in Table 15 The programming editing interface is displayed on the software only when p...

Page 69: ...ologies Co Ltd User Guide of RFL A6000D 10000D 64 Figure 43 Laser operating mode selects the display area interface Table 15 Laser operating mode and explanation Mode selection Mode explanation User mode A concise software interface ...

Page 70: ...ers subject to valid password 8 7 Language Laser s language selection interface is shown in figure 44 User can choose between simplified Chinese and English by clicking setting language Setting effective after PC software restarted Figure 44 Language selection interface 8 8 Authorization time limited locking 8 8 1 Authorization on user mode The authorization settings in user mode are shown in Figu...

Page 71: ...set the effective use time of the laser for example the lock time May 21 2020 means the laser is locked until 0 0 on May 21 2020 0 0 on May 0 2000 means the laser is permanently unlocked b The terminal password is set for the laser locking party The terminal code can only be set once and no modification is allowed after its set The terminal password is 8 byte hete e g 0123456789ABCDEF no other cha...

Page 72: ...ttings operating interface on authorization mode 8 9 About Laser relevant information such as date of manufacture model serial number controlling serial number token version number system information and other information can be queried in the PC software about item Specific interface is shown in Figure 47 ...

Page 73: ...evant information query interface 8 10 XP1 interface status indication in diagnostic mode The laser interface status indicator interface is shown in Figure 48 It is convenient to view the interface status information which represents the input and output status of the XP1 interface on the back panel ...

Page 74: ...ser Guide of RFL A6000D 10000D 69 Figure 48 The interface status in diagnostic mode 8 11 Log in diagnostic mode Laser s working log interface is shown in Figure 49 User can query work log by entering the time to query and click on the search button ...

Page 75: ...ycus Fiber Laser Technologies Co Ltd User Guide of RFL A6000D 10000D 70 Figure 49 Laser s working log interface 8 11 1 Download log Log download interface is shown in Figure 50 Figure 50 Log download interface ...

Page 76: ...interface 8 11 3 Downloaded file address The file address query interface for all download information is shown in Figure 52 Figure 52 the file address query interface for all downloaded information 8 12 Module parameters in diagnostic mode Laser module parameter query interface is shown in Figure 53 The interface is for the parameter query in diagnostic mode from which Raycus technicians can anal...

Page 77: ...Technologies Co Ltd User Guide of RFL A6000D 10000D 72 Figure 53 Module parameters query interface in diagnostic mode 8 13 Programming settings programming editing The laser programming settings interface is shown in Figure 54 ...

Page 78: ...mber of wave bars inside the current laser Operating interfaces of viewing the number of wave bar stored inside the current laser is shown in Figure 55 The software automatically lists the number of wavelength bars that have been saved by clicking on the Refresher List button Green indicates the bar already has a program and white indicates that the bar is empty ...

Page 79: ...g interfaces of wave bar stored inside the current laser 8 13 2 Check programming content To check the programming contents in the current laser programming mode is shown in Figure 56 The program automatically lists the original programming by clicking the programming number that needs to be checked ...

Page 80: ...ure 57 Interface of empty all programming stored in the current laser programming mode 8 13 4 Edit Programming Programming editing when the laser is working in programming mode as shown in Figure 58 Step 1 left click the pre edited programming number Step 2 select the command under the command type click Add Step 3 enter the parameters and click Save The instruction appears in the left program lis...

Page 81: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of RFL A6000D 10000D 76 a Select the pre edited programming number b Add command type ...

Page 82: ...Wuhan Raycus Fiber Laser Technologies Co Ltd User Guide of RFL A6000D 10000D 77 C Save command d Type the command code into laser ...

Page 83: ...ion Command meaning in laser working status is shown in Table 16 Table 16 command meaning in laser working status Code 1 Byte Parameter1 2 bytes Parameter 2 4 bytes Note 1 Stop none none The program end command the last command must be this command 2 SPT 0 65000 MS 0 65000 W Change power to 2 in time 1 3 SPR 0 65000 W MS 0 65000 W Change power to 2 in power change ratio 1 4 WAIT 1 Wait for sync si...

Page 84: ...ync signal high level output 7 EXT Power 1 0 10V 2 9 Warranty Repair and Return 9 1 General Warranty After all the products manufactured are delivered according to the order or specifications Raycus will guarantee the products to be free from any material and technical problems and ensure that they meet the specifications under Normal use Raycus has the right to selectively repair or replace any p...

Page 85: ...ompanies WARNING It is the customer s responsibility to understand and follow operating instructions in this User Guide and specifications prior to operation failure to do so may void this warranty Accessories and fiber connectors are not covered by this warranty 9 3 Service and Repair This product has no built in parts for user maintenance so all maintenance should be carried out by Raycus techni...

Page 86: ...RFL A6000D 10000D 81 The above product warranty and service terms of Raycus are for users reference only and the formal service and warranty contents are subject to agreement in the contract 2021 Wuhan Raycus Fiber Laser technologies Co Ltd All Rights Reserved ...

Reviews: