Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-A6000D~10000D
2
7: Electrical Hazard
1.2 Laser Safety Grade
This series of lasers are Class 4 laser instruments. The product emits laser radiation at a wavelength
of 915nm or around 915nm, and the average laser power radiated from the fiber delivery cable connector
is 6kW-~10kW (depending on laser model). Direct or Indirect exposure to high power laser radiation
causes damage to the eye or skin. Although the radiation is not visible, the beam will cause irreparable
damage to the retina or cornea, so appropriate and certified laser safety glasses must be worn whenever
the laser is emitting.
WARNING:
Users must use appropriate laser goggles when operating this device. The
laser goggles are selected according to the range of wavelength emitted from this product.
Users must select the appropriate laser goggles according to the entire range of laser
wavelengths. Please do not directly view (whether the laser Is emitting or not) the laser
output heads when laser emitting.
1.3 Optical Safety
Any dust on the end of the collimator assembly can damage the crystal of fiber delivery cable
connectoror the entire laser device.
CAUTION:
DO NOT emit when the protective cap is not removed, otherwise the lens or
crystal will be damaged.
1.4 Electrical Safety
a) Ensure that the PE line is effectively grounded, and the installation environment is safe and
reliable.