6.1. Initializing a new RV-M80-EA2 to factory defaults
Warning, this will erase all parameters, and may cause your RV-M80-EA2 to stop
working on your network.
AT&F
Loads defaults
ATRT 0 CONFIRM
Radio Type 0 for RV-M80-EA2 Radio modem
ATFC INITIALIZE ALL
Loads factory defaults into channel table
SCB INITIALIZE
Loads the channel banks with default channels
ATIO 5
Digital I/O mode
HWMODE 0
Hardware mode 0
Once the RV-M80-EA2 is ready to be used on a DART network, make sure all of
these settings are set.
ATMT 5
Hyper/DART modem type
SID xx
Set the system ID
On RV-M80-EA2, the periodic reporting must be enabled. This command is set
at the factory to enable GPS periodic reporting.
GXF 1 1
Enable periodic GPS tracking reporting
7. Data Transmission
To transmit data, send one or more bytes of data into the serial port of the
modem. When a full packet of data has been collected into the internal buffer of
the modem, or when there is a pause in the data, the modem will automatically
key its transmitter, and send the data over the air if the modem is within range of
a base station.
Serial Port Baud Rate
While the RV-M80-EA2 modem is transmitting and receiving data on the DART
network, the user may continue to send more data into the RV-M80-EA2
.
Because the buffers in the RV-M80-EA2 are full-duplex, the serial port data rate
and the over-the-air data rates are independent. The serial port baud-rates may
be set slow to accommodate legacy equipment, or set at high-speed to minimize
latency.
8. Debug Related Commands
Bench Testing
(Must be in command mode to test. Enter +++ at the keyboard to put unit into config/test mode.)
ATTD x
Various transmit test routines.
0 = Go back to normal mode. Stops the test.