Company Confidential
17
Raveon Technologies Corp.
SCB
Set Channel Bank
. Configure a channel bank or read a channel
bank.
SCB B Y C P
B
: bank number 1-10,
Y
:Entry Number
C
:Channel Number
a(optional):
P is optional. Set to “
C
”
if this entry is a control channel.
SCB X
to read and display a bank’s settings.
SCB X ERASE
will erase all entries in bank X.
SCB X Y DELETE
will delete channel Y from bank X.
SYSKEY
SET the encryption key.
Set the SYSTEM encryption key. This
is an ASCII hex representation of the 128 bit key. It must contain
32 hex characters.
SYSKEY DEFAULT
sets the factory default key.
Key, 32 hex characters.
NETKEY
SET the encryption key.
Set the NET encryption key. This is an
ASCII hex representation of the 128 bit key. It must contain 32 hex
characters.
NETKEY DEFAULT
sets the factory default key.
Key, 32 hex characters.
SID
Read Set the System ID.
Normally, this setting should not be
changed.
0-255
1
RDP
Read Dart Parameter.
RDP X where X is an index specifying
which internal parameter to read. This command is used for
system testing and diagnosis by the factory and technical support.
1
(DNA)
2
(authorization status)
3
(connection status)
4
(base
station ID)
5
(sequence)
6
(system ID)
7
(device class)
8
(LNA)
9(home)
10
(communication state)
20
(GPS mode)
21
(1PPS count)
22
(GPS status)
23
(GPS
features)
24
(TX Rate)
TABLE
Read the channel table version information.
Returns two
integers, comma separated. X, Y where X is the band code and
Y is the version of this band’s table.
5.4. GPS Related Commands
The following commands are specific to the operation of the RV-M80-EA2 when
the device has the GPS option installed.
GXF
Display/Set Feature GXF X Y
Display, set, or disable various GPS features.
X
is numeric feature code:
1 = Periodic GPS position reporting.
Y
= 0 for off, 1 for on.
1-10
1
5.5. Diagnostic Related Commands
The following commands may be helpful in diagnosing communication problems
or system performance.
GXF
Display/Set Feature GXF X Y
Display, set, or disable various GPS features.
X
is numeric feature code:
1 = Periodic GPS position reporting.
Y
= 0 for off, 1 for on.
1-10
1
5.6. Factory Default Settings
(DART Data Transceiver)
For the UHF RV-M80-EA2, model RV-M80-EA2-UC, the main factory defaults
are:
General Settings