M7 GX Quick Start Guide
11
Raveon Technologies
prefix. Default is a capitol letter V.
SLOTTIME
TDMA Slot duration.
Configure the
width of a TDMA slot. 50mS
increments.
50 - 1000
200
SLOTNUM
TDMA Slot Number.
Configure the
slot number that this radio will use to
send its data in.
1-9999
The MYID of
the unit
TRIGBITS
I/O Change Reporting.
Which bits
are used as transmission triggers.
This is a HEX number. Bit 0 is IN0, bit
1 is IN1….
0-FF
0
TDMATIME
Set/read TDMA Frame time.
The
length of one TDMA time frame, in
seconds. M7’s may transmit once per
frame, and only in their preset time-
slot.
1-3599
10
TRIGPOL
Polarity of the input bits.
0 = normal
active high operation(causes unit to
transmit when it goes high), 1 =
Inverted, active low. This is a HEX
number. Bit 0 is IN0, bit 1 is IN1….
0-FF
0
Active high
TRIGEX
Report on change.
Sets which input
bits cause a report on change. If a
particular bit is a 1, then it will trigger a
report when it changes. The input bit
must also be enable with the
TRIGBITS. This is a HEX number. Bit
0 is IN0, bit 1 is IN1…
0-FF
0
TRIGDX
Distance trigger.
Set a distance (in
meters) threshold beyond-which the
unit will transmit its position and
status. If set to 0, the unit always
reports at the TXRATE. If set to an
distance greater than zero, then the
unit reports at the TXRATE intervals if
it has moved this distance since the
last report. If it has not moved, it will
still report its position, but at the rate
set by IDLERATE. If IDLERATE is set
t 0, then the unit will not report its
position when not moving.
0-999
0
TRIGSPEED
Speeding Report.
Set a speed (in
kilometers/hour) threshold above-
which the unit will begin reporting its
position and status. Set to 0 to disable
this feature.
0-999
0
TXRATE
GPS Report Rate.
Set number of
seconds between GPS reports. This
is also the rate at which the internal
GPS will measure position, speed, etc.
1 - 9999
10