Supplied By www.heating spares.co  Tel. 0161 620 6677

3.3 

    

TO SHUT DOWN THE APPLIANCE

             

                 
    

 

3.3.1  For short periods, switch Summer/Winter switch to 

               Summer and turn off all hot taps.
                For long periods switch of the on/off switch (Fig.1).
                If the appliance is to be shut down for long periods 
                when there is a risk of freezing, then appliance 
                should be drained . Similar refi lling must be done 
                by a competent person following approved 
                procedure.
     
     

4.

       

CLEANING OF APPLIANCE OUTER CASING

      
     

4.1   

 

  Use a clean damp cloth. Do not use any abrasive 

                cleaners and with a dry  cloth lightly polish to protect 
                painted surfaces.
                Control  Panel and fi xiture can be wiped with damp 
                cloth and dried . Spray polishes must not be used on 
               control panel surfaces or switches.
                Care must be taken in preventing any liquids 
                entering the appliance.
     
     

5.        CARE OF YOUR  APPLIANCE AND SYSTEM

     

5.1     Annual servicing of your appliance is required to 

              maintain safety and effi ciency of its operation. 
              therefore it is reccommended that the appliance 
              is serviced at least once a year and that the whole 
              of the Heating System be checked at the same time 
              by a qualifi ed installer. If it is know or suspected that 
              a fault exists on the boiler then it MUST NOT be 
              used untill the fault has been corrected by a 
              COMPETENT PERSON. It is essential that the 
              Instructions in this booklet are strictly followed for safe 
              and economic operation of the boiler.

   

             SERVICING SHOULD BE CARRIED OUT BY 
              A QUALIFIED INSTALLER

              Ravenheat Manufacturing Ltd
              Chartists Way , Morley , Leeds 
              LS 27 9ET
              

    

  

2

  

 

 2.

          

OPERATING DOMESTIC HOT WATER

    
    

2.1        Select summer / Winter switch on Summer position 

    2.2        Open hot water tap. After about 3 secondsburner will 
                 always operate.
 
    2.3        Temperature of Domestic Hot Water can be varied by 
                 adjusting the water fl ow rate at the Domestic Hot water 
                 The temperature can be set between minimum ( 40°C)
                 and Maximum (60°C).
                 For maximum temerature of Domestic Hot Water leave 
                 the control Knob on Maximum position.     

    

3.

          

OPERATING HEATING AND HOT WATER

    

                  
    

3.1

        

TO SET AND ADJUST BUILT-IN TIMER MODEL SEE 

                 OPPOSITE PAGE 3
                  
    3.2        Select Summer/Winter Switch on Winter position 

    3.3        Switch on timeclock, adjust room stat and/or thermostatic 
                 radiator valves to hogh settings

    3.4       Burner will operate, temparature output of Central 
                Heating  can be adjusted by Central Heating Control 
                Knob(Fig.1). The Knob can be set between 
                minimum(40°C) and Maximum(85°C).While the 
                appliance is being used to provide Domestic Hot water, 
                the Central Heating will not operate.When Domestic 
                Hot Water is not longer required the appliance will 
                automatically revert to Central Heating and should not 
                noticeably affect the level of central heating.                
                Adjust external controls required settings.

   

NOTE :

 An Anti-cycling device is fi tted to the Heating Function.

                When the boiler reaches its set Maximum temperature it 
                will not operate on heating for about 10 minutes , but if 
                the heating temperature return  goes 20°C  below the set 
                point, the burner will restarts immediately.    
                The  domestic Hot Water Function will always operate on 
                demand.
             

Fig.1

min

Max

min

Max