![background image](http://html.mh-extra.com/html/raven/scs-460/scs-460_operators-manual_788837019.webp)
16
6)
Selecting C-SD, C-F, C-FC, C-P or C-PC.
a)
To select C-Sd, C-F, C-FC, C-P, or C-PC, press until desired code is
displayed.
b)
Momentarily depress
, the DATA display will now display
CAL SELF TEST 00
.
7)
Definition of Boom Calibration keys.
Depressing this key displays selected boom number in display.
EXAMPLE: Boom 1 will be displayed as
CAL BOOM 1 CAL
.
Depressing this key after selecting BOOM CAL changes the boom number.
EXAMPLE:
CAL BOOM 1 CAL 0
to
CAL BOOM 2 CAL 0
.
Depressing this key after selecting BOOM CAL changes the boom number.
EXAMPLE:
CAL BOOM 2 CAL 0
to
CAL BOOM 1 CAL 0
.
Enter Boom Data:
a)
Select boom
1 CAL
.
b)
Use boom width as calculated under "CALCULATING BOOM CAL".
c)
If a boom is not needed, enter a "0" for the length.
8)
Enter SPEED CAL calibration number in .
9)
Enter METER CAL calibration number in .
10)
Enter appropriate VALVE CAL calibration number (2123, 743, or 43 in .
11)
Enter the target RATE 1 (GPA) [lit/ha] {GPK} in .
12)
Enter the target RATE 2 (GPA) [lit/ha] {GPK} in .
(If you do not use a second rate, enter the same rate as RATE 1 CAL).
NOTE: RATE 2 should not be more than 20% different from RATE 1 or else spray
pattern may suffer.
PROGRAMMING THE CONSOLE IS NOW COMPLETED.
The flashing "CAL" will now extinguish. If not, repeat procedure starting at Step 7.
After the console is programmed, if there is a need to change initial console programming
(working units, speed sensor programs or valve drivers), hold
for 30 seconds.
The display will flash the current program setting. Press
to switch to the de-
sired selection. Press to complete entry. Repeat procedure as necessary for
speed (SP1, SP2) and valve driver selections (C-SD, C-F, C-FC, C-P, C-PC).