DATA LOGGER TRIGGER UNITS
a)
Display will show
DATA LOG TRIGGER UNITS FEET [METER]
.
b)
Depressing
momentarily changes the display between
DATA LOG
TRIGGER UNITS FEET [METER]
and
SEC
. DATA LOGGER TRIGGER VALUE has
been programmed previously. (SEC means seconds has been chosed as the unit
of measure.)
c)
Momentarily depress to advance to DATA LOGGER.
12)
DATA LOGGER ON/OFF
a)
The DATA LOGGER uses the communications strings listed in Appendix 9 to
pass data out through the serial port. The data is sent at a set time
interval or a set distance traveled, as determined by the values entered
in the DATA LOGGER TRIGGER VALUE and DATA LOGGER TRIGGER UNITS. Upon each
trigger, the Actual Rate string, Data Strings 1, 2, and 3, and the Time/
date string are sent, in that order. When a Console calibration value is
changed, the Console will automatically send out the Cal 1, 2, and 3
strings. When a Console switch is changed, the Data 1, 2, 3, Time/Date,
and Cal 1, 2, 3 strings will be sent by the Console. The Data, (with Time/
Date string included) and Cal strings can also be requested by the data
logger using the request strings shown in Appendix 9.
NOTE: Some options within the DATA MENU LISTINGS may be unavailable if certain
features are on or active. The options affected are:
CONSOLE DATA PRINTOUT:
Console Data Printout will not be available when DATA
LOGGER is ON or when GPS functions are active.
GPS OPTIONS:
GPS options will not be available when DATA LOGGER is
ON.
DATA LOGGER:
DATA LOGGER will not be available when GPS functions are
active.
b)
Display will show
DATA LOG OFF
.
c)
Depressing momentarily changes the display between
DATA LOG OFF
and
ON
. A value of
OFF
means DATA LOGGER is disabled; a value of
ON
means DATA LOGGER is enabled.
d)
Momentarily depress
to advance to PRESSURE CALIBRATION.
13)
PRESSURE CALIBRATION OF THE PRESSURE TRANSDUCER
Used to set the zero point of the pressure transducer for pressure display.
a)
Display will show PRESS ENTER TO CAL PRESSURE. Press
.
b)
Display will show ENTER SYSTEM PRESSURE.
c)
Enter actual system pressure and press
.
d)
Momentarily depress
to advance to OFF RATE PERCENT 30.