RAVEN MPV-7100/7100S OWNER’S MANUAL
IMPORTANT INFORMATION ABOUT SYSTEM FUSES
WARNING!
THIS SYSTEM IS EQUIPPED WITH SEVERAL FUSES THAT PROTECT THE ELECTRICAL SYSTEM AND
COMPONENTS FROM SEVERE DAMAGE IN THE EVENT OF A SYSTEM FAILURE. PLEASE NOTE THAT IF ANY OF
THE FOLLOWING OCCUR DO NOT ATTEMPT TO SERVICE OR REPLACE THE FUSES YOURSELF. IMMEDIATELY
CALL DGP FOR ASSISTANCE TO AVOID PERSONAL INJURY OR FURTHER DAMAGE TO YOUR MPV!
The fuses are located as indicated in the diagram below.
Note the appearance of good 20 and 30A fuses in the image below.
PROB LEM
C AUSE
SOLUT I ON
All function normal but deck will not
turn on
B l o w n 100A d e c k f u s e
C a l l D G P i m m e d i a t e l y .
Do NOT
attempt to service as this can result in
an unsafe condition.
All function normal but unit will not
drive forward
B l o w n 100A d r i v e f u s e
C a l l D G P i m m e d i a t e l y .
Do NOT
attempt to service as this can result in
an unsafe condition.
All function normal but unit does not
function in battery mode
B l o w n 75 A 4 8 V b a t t e r y f u s e
C a l l D G P i m m e d i a t e l y .
Do NOT
attempt to service as this can result in
an unsafe condition.
12V DC outlet on Generator panel
provides no power
T r i p p e d 10A c i r c u i t b r e a k e r
Push to reset breaker on the generator
panel above the 12V DC outlet.
2 0 & 3 0A F USES
NOTE:
If the 20A fuse is blown, the unit will appear totally "dead". Attempt to start the engine. If nothing happens, turn
the key to electric only mode and attempt to drive the MPV, again if nothing happens the 20A fuse may have
blown and should be replaced. See page 42.
Unit does not function at all (dead
silence)
B l o w n 2 0A ( Y e l l o w ) f u s e
Replace the 20A Yellow fuse. (See
page 42).
NOTE:
The 30 A fuse protects the system in case the 12V battery shorts or if there is a failure in the voltage regulator.
If the 30A fuse is blown, the unit will not recharge during normal use and plugging in the provided charger will
be ineffective as the 12V DC outlet on the generator panel will not function.
Starter battery does not recharge and
12V DC outlet provides no power
B l o w n 3 0 A ( G r e e n ) f u s e
Replace the 30A Green fuse. (See
page 42).
I F Y OUR PROB LEM I S NOT ON T H I S LI ST , VI SI T WWW. RAVENAMERI C A. C OM OR C ALL 1-8 8 8 -3 2 1-5 700.
t
roubleshootIng
4 6
2 0 & 3 0A F u s e s
10A C i r c u i t B r e a k e r