CHAPTER 3
INSTALLATION
MOUNT THE FLOW METER
1. Mount the flow meter in the area of the boom valves as shown in Figure 1. All flow through the flow meter must
go to the booms, (i.e. no return line to tank or pump after flow meter).
2. Mount the flow meter horizontal to the ground.
3. For best results, allow a minimum of 7-1/2” [20 cm] of straight hose on inlet of flow meter. Bend radius of hose
on outlet of flow meter should be gradual.
4. Flow must be in direction of arrow on flow meter.
FIGURE 1. Flow Control System
To ISObus
Control Harness
To sections 6 through 16