016-0171-724 Rev. A
17
SYSTEM OPERATION
WINTERIZING THE FORCE
®
EVO INJECTION SYSTEM
1. Flush and rinse the Force
®
Evo injection system.
2. Connect the clean out hose to the quick coupler for the upper, left container in the injection cabinet.
3. Place the open end of the clean out hose into a container of antifreeze designed for recreational vehicles (R.V.
antifreeze).
4. If a Raven control console is installed for carrier control, enter a self test speed of 6 mph [10 km/h] and set the
injection pump to automatic control mode.
NOTE:
Refer to the Raven control console manual for details on entering and using the self test speed
feature. The self test speed will clear if any signals are received from an actual speed sensor. To keep
the self test speed from clearing during the rinsing procedure.
5. Set the 3-way valve to the point of injection to route liquid into the carrier lines.
6. Set the carrier control to a normal rate during this procedure.
7. Toggle the injection pump to automatic control mode.
8. Toggle the master switch and at all section switches to the on position.
9. Run the injection pump for 2 minutes.
10. Toggle the injection pump to the off position.
11. Move the clean out hose to the next coupler and repeat step 7 through step 11 until all couplers in the injection
cabinet have antifreeze in the lines.
NOTE:
Use caution not to run out of antifreeze during this procedure.
Summary of Contents for Force Evo
Page 1: ...Copyright 2019 Force Evo Injection System Installation Manual 016 0171 724 Rev A 12 20 E36393 ...
Page 4: ...Table of Contents ii Force Evo Injection System Installation Manual ...
Page 10: ...CHAPTER 2 6 Force Evo Injection System Installation Manual ...
Page 22: ...CHAPTER 4 18 Force Evo Injection System Installation Manual ...
Page 30: ...CHAPTER 5 26 Force Evo Injection System Installation Manual ...