9
Setup Issues
Job Issues
Issue
Possible
Cause
Solution
Previous
calibration data
lost
Poor CAN
connections
Refer to the “CAN Troubleshooting”
Issue
Possible
Cause
Solution
Section status
displays as
inactive
CAN Switch Box
switches in the
off position
Toggle the section and master switches
to the on position.
Automatic
section control
enabled but
sections do not
turn on
Check the speed sensor connection on
the back of the CAN Switch Box.
Move vehicle into a previously
unapplied area and maintain a speed of
at least
0.7 mph [1.1 km/h].
Enable the Override feature on the
control console or field computer
Section status
does not turn
green (ON)
when sections
enabled
Master switch
must be toggled
off at power-up
Cycle the master switch off then back
on.
Sections not
properly
configured
Verify section setup on the control
console or field computer.
Nodes not
programmed
properly
Verify all node calibration data is
entered.
Product function
switches do not
work
Master switch
must be toggled
off at power-up
Cycle the master switch off then back
on.
Product
application
turned off
Toggle product control switches to
AUTO or MAN mode to turn product(s)
on.