CHAPTER 4
28
Hawkeye® 2 Installation Manual for AGCO RoGator C-Series (RG900, RG1100, RG1300)
INSTALL THE PROSTOP-E VALVE
NOTE:
For the Wilger version of
Hawkeye® 2 kits
, the
Hawkeye® 2
system will control the Hypro ProStop-E
on/off valve in addition to the NCV. In order to accommodate both valves, a Wilger dual drop nozzle
body is installed along with an adapter for the ProStop-E.
1. Install the four O-rings into the ProStop-E adapter.
FIGURE 7. ProStop-E Adapter O-Ring Installation
2. Remove the ProStop-E valve from the original Hypro nozzle body by removing the U-clip that attaches it to the
threaded nut. Pull on the valve to separate it from the nut, and spin the nut to remove it from the nozzle body.
NOTE:
Leave the ProStop-E connected to the existing cabling.
3. Remove the Hypro Nozzle body from the boom tubing.
4. Thread the ProStop-E adapter (P/N 063-0173-964) onto the threaded port of the Wilger nozzle body furthest
from the boom tube clamp.
FIGURE 8. ProStop-E Adapter Installation Location
#2-011
#2-117
(Largest)
#2-116
#2-111
Summary of Contents for AGCO RoGator Hawkeye C Series
Page 8: ...CHAPTER 1 4 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Page 24: ...CHAPTER 2 20 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Page 26: ...CHAPTER 3 22 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Page 52: ...CHAPTER 6 48 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Page 56: ...CHAPTER 7 52 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Page 60: ...APPENDIX A 56 Hawkeye 2 Installation Manual for AGCO RoGator C Series RG900 RG1100 RG1300...
Page 62: ......