background image

Page 7

Example of Cavity Design - T

op V

iew

1.

Angle section for support 

fi xed to timber frame/

fl oor using coach screws or ‘Dynabolts’ when 

fi xing to concrete.

2.

The joint for 

fi re rated board* and Plasterboard located over frame member must be stopped to manufacturer’s instructions.  Note: Wallpaper is

 not permitted on 

the

 

front of the enclosure.

3.

Comply with all minimum distance to all combustible surfaces.  Any modi

fi cations to the dimensions shown to be veri

fi ed by consultation with the relevant Building

Consent Authority

.

4.

Ensure there is a minimum of 

2 x 

100cm

2

 

ventilation into the cavity (this does not need to be from 

the outside).

5.

Installers must ensure adequate vermin proof measures are incorporated into the cavity construction (if applicable).

*Ensure product being used is 

fi reproof rated above 80°C eg

 Pro
m

iaa

 Micore, Supalux, Eterpan 

or 

similar

NOTES

15

0mm

15

0mm

100mm

Pr

omina boar

d*

Pr

omina boar

d*

1. 

Angle

 section

 for

 support

 fixed
 to

 timber

 frame

 / floor
 using

 coach

 scr

ews
 or

 ‘Dynabolts’

 when

 fixing

 to

 concr

ete.

2. 

The

 jo

int

 fo

r fi

re r

ate

d b

oa

rd

* a

nd

 P

las

ter

boa

rd

 lo

cat

ed

 ov

er f

rame

 m

emb

er m

ust

 b

e s

to

pp

ed

 to

 th

e m

anu

fac

tu

rer

’s in

st

ruc

tio

ns

. N

ote:

 W

allp

ap

er  

 

is not

 permitted

 on

 the

 fr

ont

 of

 the

 enclosur

e.

 

3. 

Comply

 with
 all

 minimum

 distance

 to

 all

 combustible

 surfaces.

 Any
 modifications

 to

 the

 dimensions

 shown

 to

 be

 verified

 by

 consultation

 with
  

 

the

 relevant

 Building

 Consent

 Authority

.

4. 

Ensur

e ther
e is

 a minimum

 of

 2 x

 100cm

2

  ventilation

 into
 the

 cavity

 (this
 does
 not

 need
 to

 be

 fr

om

 the

 outside).

5. 

Installers

 must
 ensur

e adequate

 vermin

 pr

oof

 measur

es

 ar

e incorporated

 into
 the

 cavity

 construction

 (if

 applicable).

 

*Ensur

e pr

oduct

 being

 used
 is

 fir

epr

oof

 rated

 above

 80

o

Ceg. Pr

omina Micor

e, Eterpan or similar

Summary of Contents for SOFIA

Page 1: ...nsert Wood Pellet Fire Installation Specifications Safety testing of the Ravelli Sofia Insert Wood Pellet Burning Heater to AS NZS 2918 2018 Appendix B ARS 22 3116 22 3112R1 Flue Kit Testing to AS NZS...

Page 2: ...ly installed into a masonry Cavity Dimensions Sofia Insert Built In Heater Refer to Safety Test ARS 22 3116 22 3112R1 for all clearances to combustible 713 5 610 541 5 112 400 78 590 14 527 5 541 5 17...

Page 3: ...N Wall Opening D Width 760 mm E Height 625mm Additional Clearances to Combustibles K from exhaust spigot to cavity wall 100mm L from side of fire to cavity wall 150mm M hearth depth from front of glas...

Page 4: ...oduct being used is reproof rated above 80 C eg Promiaa Micore Supalux Eterpan or similar NOTES 150mm 150mm 100mm Promina board Promina board 1 Angle section for support fixed to timber frame floor us...

Page 5: ...alled In the event of failure to respect these precautions Pellet Fire Solutions declines all responsibility 1 The fire must be installed on a oor with suf cient carrying capacity If the existing buil...

Page 6: ...mbustible Mantle To be zero rated using eterpan e with a 12mm air gap to comply AS NZS 2918 2018 10 Before connecting the pellet fire electrically the connection of the exhaust spigot must be complete...

Page 7: ...oach screws Thickness of ooring must be 20mm minimum The ooring shall be xed to the nearest joist with two 8g x 40 screws per hold down anchor Fixing to Timber Floor Framing Minimum 14g x 60 screws 6...

Reviews: