Page 2
joints must be riveted using stainless steel rivets.
10. Before connecting the pellet fi re electrically, the
connection of the exhaust spigot must be completed
(specifi cally for non-aluminium pellet fi res) with the
fl ue. (All fl ue joins must be sealed with Maniseal
exhaust cement).
11. Seismic Restraint - please see “ Seismic Restraint”
to see what is required.
12. Warranty - To validate the warranty following
installation, a copy of the completed Warranty/
Producer’s Statement must be forwarded to
Pellet
pelletfiresolutions.co.nz
@
s
n
o
it
u
l
o
S
- o
f
n
i
e
ri
F
ATTENTION
There are two critical components when installing a Sara Insert Wood Pellet
re:
1) Ensure the wall cavity is the necessary size.
2) Ensure relevant clearances to combustibles are adhered to both inside and outside the cavity.
Depending on the circumstances, you may also have to consider the use of a hearth, and the installation
of a support frame
.
TELEVISION
CLEARANCES
Television
If electrical equipment (eg Plasma TV, LCD TV or home
theatre) is to be installed above the wood pellet fi re, we
recommend installing a non combustible mantle below
the TV screen, or recessing the TV screen into the wall,
for heat protection.
50mm (min)
50mm (min)
The clearances shown are recommended minimums,
and are to be treated as suggestions only.
40mm
330mm
40mm
330mm
The end user is responsible for checking the installation
instructions and clearance requirements of their electrical
appliances to ensure the appliance is suitably located in
relation to the wood pellet fi re.
Pellet Fire Solutions
and
Ravelli
does not guarantee that these recommended
clearances will be appropriate for all electrical equipment
Non combustible
Mantle
To be zero rated using eterpan etc
with a 12mm air gap to comply with
AS/NZS 2918 : 2001