Architectural Drawings
Example of Cavity Design - Section View
1. Angle section for support fi xed to timber frame/fl oor using coach screws or ‘Dynabolts’ when fi xing to concrete.
2. The joint for fi re rated board* and Plasterboard located over frame member must be stopped to manufacturer’s
instructions. Note: Wallpaper is not permitted on the front of the enclosure.
3. Comply with all minimum distance to all combustible surfaces. Any modifi cations to the dimensions shown
to be verifi ed by consultation with the relevant Building Consent Authority.
4. Ensure there is a minimum of 100cm
2
ventilation into the cavity (this does not need to be from the outside).
5. Installers must ensure adequate vermin proof measures are incorporated into the cavity construction (if
applicable).
*Ensure product being used is fi reproof rated above 80°C eg Micore, Supalux, Eterpan or similar
NOTES
*
330mm
~648mm
~200mm
~300-580mm
12mm ‘Micore’ board*
12mm ‘Micore’ board*
100mm
550mm
300
-
530mm