background image

Safety InformatIon

The stove must be installed and inspected by specialist staff trained by head 
office. Please carefully read this user and maintenance manual before installing 

and operating the stove. If you require further clarification, contact your nearest 
Ravelli srl dealer. The stove must be located indoors, never outdoors. Because it 

is controlied by an electronic board, it enables completely automatic and uncon-
trolled combustion: in fact, the control panel regulates activation, the 5 power 
levels and switch off phase, guaranteeing safe functioning.
Most of the hot ash falls into a pan via the basket used for pellet combustion. 

Check , on a daily basis, if the basket is clean, because not all pellets are of the 
highest quality and they can leave residues which are difficult to remove.
The glass is equipped with a special air wash for self-cleaning: yet, it is impos-

sible to avoid a slight yellowish film on the glass after some hours of functioning.
As already mentioned previously, the stove should be powered with pellets with 
diameter of 6 mm, but it can also operate with pellets with different diameter: in 
this case, contact your Ravelli dealer for technical advice.

NOTE

• 

Prepare the installation location of the stove according to local, national and 

European regulations. 

• 

The stove must only be powered using high quality pellets with a diameter of 
6 mm as described in the dedicated chapter. 

 The stove cannot burn traditional wood. It is forbidden to use the stove as an 

incinerator. DANGER OF FIRE! 

• 

Installation, electrical connection, verification of functioning and mainte-

nance must be carried out by qualified and authorised staff.

• 

Improper installation or poor maintenance (non-conformity with what is 

reported in the following booklet) may cause damage to people or prop-

erty. In this condition, RAVELLI SRL is released from all civil or cr

imina

liability. 

• 

Before connecting the stove to electrical power, the connection of the dis-
charge tubes (specifically for pellet stoves, not in aluminium) with the flue 
must be complete.

• 

The protection grid placed inside the pellet tank must never be removed.

• 

There must be a sufficient exchange of air in the room in which the stove is 
installed.

• 

Never open the door of the stove when functioning. 

 DANGER OF FIRE! 

• 

It is forbidden to operate the stove with the door open or with the glass bro-

ken. 

 DANGER OF FIRE! 

• 

When the stove is working, the surfaces, the glass, the handle and the tubes 
are very hot: during functioning these parts can only be touched using ad-

equate protective equipment.

• 

Do not switch on the stove without firstly carrying out a daily inspection as 

described in the MAINTENANCE chapter of this manual.

• 

Do not dry washing on the stove.  

Any washing lines or similar must be kept an appropriate distance from the 

stove.

 

 DANGER OF FIRE! 

• 

Scrupulously follow the maintenance schedule.

• 

Do not switch off the stove by disconnecting the electrical mains.

• 

Do not clean the stove until the structure and ash are completely cold.

• 

Carry out all operations in a completely safe and calm manner.

• 

In the event of fire in the exhaust duct, switch off the stove immediately - DO 

NOT UNPLUG IT FROM THE MAINS - and call the 

fire department 

right 

away.

responsibilities

By handing over to the end user this manual, Ravelli srl denies all liability, both 
civil and criminal, for accidents arising from non-compliance with instructions 

contained in it. 
Ravelli srl denies all liability deriving from improper use of the stove, from incor-
rect use by the user, from unauthorised changes and/or repairs and from use of 

non-original spare parts. 

 The manufacturer declines all direct and indirect civil and criminal liability 

due to: 

• 

poor maintenance

• 

non-compliance with the instructions contained in this manual

• 

use not complying with safety directives

• 

installation not complying with the standards in force in the country

• 

installation by unqualified and untrained staff

• 

changes and repairs unauthorised by the manufacturer

• 

use of non-original spare parts

• 

exceptional events

6

Summary of Contents for o-ring

Page 1: ...en USER MANUAL O RING...

Page 2: ......

Page 3: ...minary Operations Wiring How to load the pellets O Ring DESCRIPTION HOW TO USE THE O RING OFF state Switch on Work phase The grate Turning off First infeed screw loading Extra fan blow Installation an...

Page 4: ...provided by the user Clean the surfaces Grate cleaning should be carried out before each switch on Cleaning the ash pan Cleaning glass Warranty Warranty Certificate Warranty conditions Info and proble...

Page 5: ...nsibility for damage caused to peo ple animals or property errors during installation regulation and maintenance and improper use No other fuel other than pellets can be used Do not use combustible li...

Page 6: ...lectrical power the connection of the dis charge tubes specifically for pellet stoves not in aluminium with the flue must be complete The protection grid placed inside the pellet tank must never be re...

Page 7: ...of water 8 10 they have a high energy content The standards DIN 51731 define the quality of the pellets Length 10 30 mm approx Residual humidity 6 12 approx Diameter 6 10 mm approx Ashes 1 5 Real weig...

Page 8: ...and must be provided externally electrical resistor on switch on Then the energy released by the reaction makes self sustainment possible Three types of combustion are reported below the correct one i...

Page 9: ...boration with Asso cosma association of stove sweepping technicians and specialists of the field in order to facilitate the installer to build a system able to evacuate fumes in accordance with the re...

Page 10: ...lue exhaust system must be supplied and installed in compli ance with the regulations issued by the standardization bodies and should be installed according to state of the art standards Air vent It i...

Page 11: ...50 Stainless Steel AISI 316 and 050 thickness 0 5mm G O Indicates the fire resistance class of unburnt products G YES O NO and the value between brackets indicates the distance from flammable material...

Page 12: ...se area mm Z Height measured in vertical plane See figure 8 B X 500 Z A A Height above the obstacle 200 Symbol Description Clearance area mm Dormer window 2 A Side distance from dormer window 1500 B H...

Page 13: ...ases are com pleted without encountering anomalies Additional documentation and informations for the user Upon installation completion the installer should hand over to the user the user s manual of t...

Page 14: ...ded as new system makeover upgrade non routine maintenance other 1 Commissioned by installedatthepremisesinthemunicipalityof prov street floor internal owned by in the building designated as industria...

Page 15: ...ents certificate of conformity for the system executed with non standard materials or systems 8 Optional annexes Photographic Documentation Use and maintenance manual of the fireplace the Fume datapla...

Page 16: ...ated if possible into the layout of the existing system The layout shall include the fire prevention protocol where applicable 7 The reference data include the name of the company that carried out the...

Page 17: ...flue for the sec tion inside the home while the section placed outside must have insulated tub ing In the lower part of the flue inside the house was nstalled a T fitting with an inspection cap anothe...

Page 18: ...ue duct be cause the latter is installed inside the building and a part of it is located inside an already existing flue duct In the lower part of the stove was intalled a T fitting with inspection pl...

Page 19: ...installation of a pellet insert In this type of installation we can notice that the fitting was used to enable connecting the insert to the chimney so called bayonet mount For safety reasons and to en...

Page 20: ...0 50 230 50 Tank capacity kg 15 17 19 Autonomy h min max 12 23 10 3 24 2 8 1 27 1 Efficiency min max 89 90 5 89 86 6 93 4 88 2 CO at 13 O2 min max 0 017 0 019 0 047 0 011 0 0234 0 010 Smoke mass g s m...

Page 21: ...Key Push button LED status indicators The O Ring graphical representation is minimal to better highlight its main fea ture simplicity In the following pages we shall see how to use the device to contr...

Page 22: ...that the O Ring features 12 powers each of them being indicated by the ignition of the 2 BLUE LEDs example of operation at power 6 example of operation at power 9 By increasing the power via the knob...

Page 23: ...lit 90 sec 18 LEDs lit 120 sec 24 LEDs lit Extra fan blow Due to its innovative O ring the Ravelli Young stove allows the user to vary the blow of room fan for each of the 12 powers of the stove This...

Page 24: ...ll not be possible to switch off the stove from the external thermo stat It will run continuously in modulation mode Below is shown the way in which the O Ring indicates this mode After reaching the s...

Page 25: ...f the operation at P7 are alternately replaced by the 24 RED LEDs every 5 seconds Operation at P7 HOT FUME signal ALARMS In the event that there is a problem in the operation of the stove the electron...

Page 26: ...the tank as they may contain burning pellets that may cause the tank to burn into flames Put the pellets in a container suitable for flammable material i g metal bucket The O Ring will display the err...

Page 27: ...ct the Support Service AL 03 FUME OVERTEMP Combustion in the brazier is not optimal due to clogging or obstructions of internal stove ducts Switch off the stove clean the brazier and the tube bundle a...

Page 28: ...ect the power cord with the stove in Switched OFF state make sure all the parts of the stove are cold make sure the ash is completely cooled PLEASE READ CAREFULLY THE FOLLOWING INSTRUCTIONS TO PER FOR...

Page 29: ...he pellets used and the frequency of use It may be necessary to carry out these operations on a daily basis Cleaning glass The glass of the door should be cleaned with the stove cooled down using a co...

Page 30: ...or cast iron the resistor the coloured majolica any damage due to inadequate installation and or tampering with the stove and or negligence on the customer s part Use of poor quality pellets or any ot...

Page 31: ...E F C S C S F COCLEA VENT SCAMBIATORE VENT FI wiring diagram DEP VACUUM METER TSP PELLET TANK SAFETY THERMOSTAT to ensure proper operation please observe the polarity of the thermocouple FUME ENCODER...

Page 32: ...Note...

Page 33: ...Note USER MANUAL O RING 33...

Page 34: ...Note 34...

Page 35: ......

Page 36: ...let and considers itself free to make any variations to the features of its products without notice Ravelli srl via Kupfer 31 25036 Palazzolo sull Oglio BS ITALY Tel 39 030 7402939 Fax 39 030 7301758...

Reviews: