background image

Use and maintenance manual for stoves with RDS technology

Pag.5 

Rev.0 05/12/2022

SAFETY INFORMATION

The stove must be installed and tested by specialized personnel instructed by the Ravelli. Please read this use and 

maintenance manual before installing and putting the stove into operation!

If you require further information, please contact your Ravelli dealer.

IMPORTANT

The place of installation of the stove must comply with local, national and Federal regulations.

The stove must be fuelled only with quality pellets with a diameter of 6 mm as described in the specific chapter.

The stove cannot operate with traditional wood

The stove must not be used as an incinerator. FIRE HAZARD!!!

Installation, the electrical connections, checking the functioning and maintenance must be performed by qualified and 

authorized personnel.

Improper installation or poor maintenance (not compliant with what is shown in the following manual) may cause damage 

to persons and things. In this condition, Ravelli is relieved of all civil or criminal responsibility.

Before connecting the stove electrically, the connection of the exhaust tubes must be completed (specifically for pellet 

stoves, not made from aluminium) with the flue.

The protection grille inside the pellet hopper must never be removed.

There must be sufficient circulation of air in the room where the stove is installed.

Never open the door of the stove whilst it is functioning. FIRE HAZARD!!!

The stove must not be used with the door open or with the glass broken. FIRE HAZARD!!!

When the stove is operating, the surfaces, the glass, the handle and the pipes become overheated: during functioning, 

these parts must only be touched with the adequate protection.

Do not light the stove without having first performed the daily inspection as described in the MAINTENANCE chapter of this 

manual.

Do not place any washing on the stove to dry. Keep clothes and similar at a suitable distance from the stove. FIRE HAZARD!!!

DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE.

DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.

DO NOT INSTALL A FLUE DAMPER.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

Attachment and securement of the exhaust venting system to the product and to each adjoining section. All joints for 

connector pipe shall be required to be fastened with at least three screws. If vented horizontally, joints shall be made 

gaslight in a manner that shall be specified.

Perform regular inspection, maintenance, and cleaning of the chimney and chimney connector

Disposal of Ashes: Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should 

be placed on a non-combustible floor or on the ground, well away from all combustible materials,  and moved outdoors 

immediately. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the 

closed container until all cinders have thoroughly cooled. Other waste shall not be placed in this container.

Caution against the storage or use of flammable liquids, as follows: Never use gasoline, gasoline-type lantern fuel, kerosene, 

charcoal lighter fluid, or similar liquids to start or ‘freshen up’ a fire in this heater. Keep all such liquids well away from the 

heater while it is in use. 

Creosote - Formation and Need for Removal

When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form 

creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote 

residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire

The exhaust venting system should be inspected at least once every two months during the heating season to determine 

if a creosote buildup has occurred.

If creosote has accumulated it should be removed to reduce the risk of a chimney fire.

Scrupulously follow the maintenance programme.

Do not switch off the stove by disconnecting the electricity mains supply.

Do not clean the stove until the structure and the ashes have cooled down completely.

Carry out all operations in maximum safety and tranquillity.

Coply with exhaust venting system termination requirements including location restrictions to air inlets, distances from 

windows, doors, and air inlets and distance to combustible materials. 

DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY 

APPROVED FOR SUCH INSTALLATIONS.

Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns.

The type of chimney shall be suitable for solid fuel and the chimney connector must be in good condition and kept clean.

Establish a routine for the fuel, pellet burner and fring technique. Check daily for creosote build-up until experience shows 

how often you need to clean to be safe. Be aware that the hotter the fire the less creosote is deposited and weekly cleaning 

may be necessary in mild weather even though monthly cleaning may be enough in the coldest months. Contact your local 

or fire authority for information on how to handle a chimney fire. Have a clearly understood plan to handle a chimney fire.

Keep firing and deashing doors closed and maintain all seals in good conditions.

Do not strike or slam shut the door, the glass can brake. The glass shall be cleaned only when cold, do not clean a hot glass. 

Use a dry cloth with normal glass detergent, do not use any abrasive cleaner.

The type of chimney shall be suitable for solid fuel and the chimney connector must be in good condition and kept clean.

When this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation 

Summary of Contents for Francesca 2015

Page 1: ...USE AND MAINTENANCE MANUAL Stoves with RDS technology Francesca RV 80 Ceramica Nicole RV 100 Classic Roma...

Page 2: ...ns could result in property damage bodily injury or even death Contact local building or fire officials about restrictions and installation inspection requirements in your area Contact local authoriti...

Page 3: ...tallation only for pellet fireplace insert 17 Minimum opening for masonry and manufactured fireplace only for pellet fireplace insert 20 Standard horizontal installation configurations 21 DESCRIPTION...

Page 4: ...the Technical service This stove must be used for the purpose for which it has been specifically manufactured Do not use the appliance as an incinerator or in any way other than that for which it was...

Page 5: ...terials and moved outdoors immediately If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly c...

Page 6: ...ne if cleaning is necessary GENERAL The Stove must only operate in rooms As it is controlled by an electronic board combustion is completely automatic and controlled and the control unit regulates the...

Page 7: ...nnot be used They must always be protected from the damp both during transport and in storage Do not place such fuel within the space heater installation clearances or within the space required for ch...

Page 8: ...n blowtorch style with a high quality of incandescent pellets coming out of the grate Correct the pellet air set by reducing the percentage of air from 0 to 5 if not sufficient also increase the perce...

Page 9: ...ESIGNER DATA DRWG NR N DISEGNO DATE CAD DRAWNING HANDLING ON CAD SYSTEM ONLY TRATTAM SUPERFICIALE Posizione file di disegno X ECO PROGETTI 00_STUFE ARCHIVIO VALIDI MODELLI SW 1 014 ASS PORTA MONTATA V...

Page 10: ...1 5 Width Inch 17 32 17 4 20 20 21 7 43 4 Depth Inch 18 46 19 6 19 1 21 9 29 5 Weight Lbs 200 253 270 320 550 Diameter of smoke exit tube Inch 3 14 3 14 3 14 3 14 3 14 Min max hourly consumption of pe...

Page 11: ...closet or similar conceald space or a floor or ceiling Where passage through a wal or partition of combustible construction is desired the installationshall conform to CAN CSA B365 The stove must be i...

Page 12: ...from any forced air intake of any other appliance G Minimum 2 clearance below eaves or overhangs H Minimum 1 clearance horizontally from combustible wall X Must be a minimum of 2 above the roof ridge...

Page 13: ...9 0 4 0 3 5 2 2 0 3 9 8 8 2 7 8 7 9 5 6 3 1 8 7 5 3 2 8 3 5 8 0 1 0 7 8 3 4 7 8 9 4 5 3 7 M o d D E S C R I Z I O N E D a t a D i s A p p r M O D I F I C H E 5 4 0 0 0 0 0 0 0 1 M O D _ _ A 1 S C H E...

Page 14: ...P E R Q U O T E L I N E A R I A N G O L A R I S M U S S I E R A C C O R D I C L A S S E F I N E U N I E N 2 2 7 6 8 1 D O V E N O N I N D I C A T E 1 5 F C H P B e l o t t i v e n e r d 1 4 s e t t e...

Page 15: ...ing from floor F Corner from stove Side wall from stove Rear side wall from stove Ceiling from floor Front D Side E Unit of measurement Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm...

Page 16: ...y be made of combustible material G B E Wall may be made of combustible materials zero clearance Combustib K Combustible floor Minimum distance from combustible material for pellet fireplace insert Ro...

Page 17: ...tion on the top of the plate to reduce the possibility of condensation This fireplace has not been tested with unvented Gas log set To reduce risk of injury do not install an unvented gas log set into...

Page 18: ...Use and maintenance manual for stoves with RDS technology Pag 18 Rev 0 05 12 2022 Use only 45 or 30 bends do not use 90 bends...

Page 19: ...rom the insert to the top of the chimney The chimney liner must be conform to the class 3 require ments of CAN ULC S635 Standard for Lining Systems for ExistingMasonry or Factory Built Chimneys and Ve...

Page 20: ...over plate non combustible B L vent flex section C The smoke baffle damper and shields may be removed if attached with mechanical fasteners D The metal sides frame members or other structural compo ne...

Page 21: ...a section of PL pipe until inner pipe liner pushes into the bead of RTV sealer 3 Push the stove with pipe attached towards the wall the pipe will go through the wall thimble Do not position the back o...

Page 22: ...m clearance between wall and pipe If you vent to the furthest wall the vent pipe must maintain a 3 clea rance parallel to the other wall Top View Illustration Notes It is not recommended to ter minate...

Page 23: ...e unavoidable inconveniences will disappear after the first hours of operation To reduce your discomfort to a minimum keep the stove on for a few hours on low power and in the beginning do not overloa...

Page 24: ...he display recommended for use with wall mounted display only With external thermostat Press key 1 from the Home screen to enter the room temperature setting page Set the desired temperature with keys...

Page 25: ...s still hot i e in FINAL CLEANING the stove will remain in the WAITING RESTART phase for a few minutes after which it will automatically re ignite IGNITION RESTART Modulation During the work phase the...

Page 26: ...r service during inspection To go to the second screen press key 1 From the first screen it is possible to activate the initial loading of the auger by pressing key 2 The Screw Status value will becom...

Page 27: ...stoves it is possible to set the temperatures of the individual rooms F front temperature of the stove installation room R Rear single duct room temperature heated by ducting RL and RR Rear Left and R...

Page 28: ...1 30 Power 3 Room temperature 21 C Activation days Saturday and Sunday Switch on at 9 00 Switch off at 12 00 Power 5 Room temperature Regulated by an external thermostat The Comfort Clima function als...

Page 29: ...he set value in this case 5 C activated the Comfort Clima function OPERATION The value adjusts the re ignition temperature of the stove EXAMPLE room temperature set at 21 C Comfort Clima value set at...

Page 30: ...LF CONTROL SYSTEM S C S Enable or disable the function by using key OK Mode SELF CONTROL SYSTEM S C S has been realized allowing the stove to recognize faster an eventual problem just in case you are...

Page 31: ...the stove appropriately By accessing the menu the adjustment of the draft pellet mixture is displayed To change the percentage use buttons 1 and 2 to switch from adjusting the quantity of pellets to a...

Page 32: ...To facilitate cooling the stove brings the capacity to a minimum with ventilation at max power level OFF The stove is off ANOMALY general The stove has detected an anomaly refer to the troubleshooting...

Page 33: ...o read the quantity of inlet air could be disconnected or defect Please contact the local Technical Assistance Centre The device could be dirty and so not read cor rectly Please contact the local Tech...

Page 34: ...with reset 1 By pressing the button OK on the display the alarm can be reset 2 Unscrew the protection cap and press the button to reset the thermostat alarm 3 Try and repeat lighting after the coolin...

Page 35: ...ELETTRONICA 24 ottobre 2016 11 24 34 Via Kupfer 25036 Palazzolo S O BRESCIA ITALY MICROINTERRUTTORE MK V11D09 COD 55536 Mod DESCRIZIONE Data Dis Appr MODIFICHE 55536 MOD _ _ A3 SCHEET FORMATO TOLLERA...

Page 36: ...eased to other parties without written consent any infringement in any way utilized for the manifacture of the component of unit herein illustrated All proprietary right reserved by Society ECOTECK s...

Page 37: ...tion takes place is clean and that no waste or residue blocks the holes in order to always guarantee excellent combustion of the stove thus avoiding possible overheating which could causes changes in...

Page 38: ...usted with a soft brush to remove the ash that is deposited during combustion Abrasive sponges to clean to most resistant waste should not be used as they could compromise the thickness of the FIREX60...

Page 39: ...the Majolica cladding the aesthetic parts any damages caused by unsuitable installation and or use of the product and or shortcomings on the part of the customer The use of poor quality pellet or any...

Page 40: ...any variations to the features of its products and to the present manual without notice Aico S p A Headquarter Via Consorzio Agrario 3 25032 Chiari BS Italy Research and Development Centre Viale del c...

Reviews: