Use and maintenance manual Flexi 11
Pag.43
Rev.1 04/03/2021
Ventilation menu
The stoves with optional fan use the natural convection system which guarantees a considerable amount of heat in the room with the total
absence of noise given by the room ventilation. However, there is the possibility, by accessing the menu below, to activate the optional
ventilation according to the power requested by you.
Below are the steps to follow, starting from the Home screen, to access the relevant menu.
Press the key repeatedly to go back to the “Home” screen.
Ventilation can be set to 0 (disabled). The setting from 1 to 5 allows the choice of the heat propagation speed. If the value is set to
AUTO, the ventilation follows the power set on the stove.
📌
If the AUTO function is not set, the fan is independent from the stove power. When the stove goes into modulation mode,
the exchanger goes to minimum.
Single ducting
📌
This function must be set up by a technician that is qualified and/or authorised by the Manufacturer.
This function allows you to manage distribution of warm air between the room where the stove is installed and the room where the duct
arrives.
The function has two operating modes: manual and automatic.
Manual mode: the user manually sets distribution of warm air between front ventilation and ducting.
Automatic mode: the stove automatically manages distribution of warm air between front ventilation and ducting, according to the tempe-
ratures in the rooms.
Manual management
Below are the steps to follow, starting from the Home screen, to manage ventilation and ducting manually:
To exit the screen to go back to the CANALIZED menu, press the “back” key once; to go back to the Home screen, press
the “back” key several times.
Press the
“increase/decrease” keys
to modify the ventilation.
Press the
“Access to menu” key to
access the MENU screen
Press the
“confirm” key
to access the
USER screen
Press the
“confirm” key
to go to the item
VENTILATION.
MENU
USER
TECHNICIAN
PRODUCER
USER
VENTILATION
LOADING AUGER
CHRONOTHERMOSTAT
SET AIR-PELLET
Press the
“increase/decrease” keys
to modify ventilation.
Press the
“confirm” key
to go to the item
REAR
Press the
“increase/decrease” keys
to modify ducting.
Press the
“Access to menu”
key to access the
MENU screen
Press the
“confirm” key
to access the
USER screen
Press the “confirm” key
to go to the item CANALIZED.
Press the “decrease” key to go to
the item VENTILATION
MENU
USER
TECHNICIAN
PRODUCER
USER
CANALIZED
LOADING AUGER
CHRONOTHERMOSTAT
SET AIR-PELLET
CANALIZED
MANAGEMENT
TEMPERATURE
VENTILATION
CUBAGE
STATUS DISPLAY